background image

TECHNICAL DATASHEET

 

Sync DIN Rail Power Supply 

24V 30W 1 Phase (NEC Class 2) / DRS-24V30W1NZ

 

 

 

  

All parameters are specified at 25°C ambient and AC input unless otherwise indicated.

 

  www.DeltaPSU.com (July 2019, Rev. 04) 

 

13

 

Others 

Delta RoHS Compliant 

Restriction of the usage of hazardous substances 

The European directive 2011/65/EU limits the maximum impurity level of homogeneous materials such as lead, 

mercury, cadmium, chrome, polybrominated flame retardants PBB and PBDE for the use in electrical and 

electronic equipment. RoHS is the abbreviation for “Restriction of the use of certain hazardous substances in 

electrical and electronic equipment”. 
This product conforms to this standard. 

 

 

Attention 

Delta provides all information in the datasheets on an “AS IS” basis and does not offer any kind of warranty through the information for 

using the product. In the event of any discrepancy between the information in the catalog and datasheets, the datasheets shall prevail 

(please refer t

www.DeltaPSU.com

 for the latest datasheets information). Delta shall have no liability of indemnification for any claim 

or action arising from any error for the provided information in the datasheets. Customer shall take its responsibility for evaluation of 

using the product before placing an order with Delta. 
Delta reserves the right to make changes to the information described in the datasheets without notice. 
 

 

 

Содержание DRS-24V30W1NZ

Страница 1: ...IN rail power supply series is designed for industrial applications requiring highly reliable power supply within a tight space The Sync series operates with universal AC input range and offers full p...

Страница 2: ...test conditions for DC input Safety approval for DC input can be obtained upon request Output Ratings Characteristics Nominal Output Voltage 24Vdc Factory Set Point Tolerance 24Vdc 2 Output Voltage A...

Страница 3: ...ting Humidity 5 to 95 RH Non Condensing Operating Altitude 0 to 2 000 Meters 6 560 ft Shock Test Non Operating IEC60068 2 27 Half Sine Wave 50G for a duration of 11ms 3 times per direction 9 times in...

Страница 4: ...s Safety Entry Low Voltage SELV EN 60950 Electrical Safety TUV Bauart EN 60950 1 EN 62368 1 UL cUL recognized UL 60950 1 UL 62368 1 CSA C22 2 No 60950 1 File No E191395 CB Scheme IEC 60950 1 IEC 62368...

Страница 5: ...ia A1 2kV Surge IEC 61000 4 5 Level 3 Criteria A1 Common Mode3 2kV Differential Mode4 1kV Conducted IEC 61000 4 6 Level 3 Criteria A1 150kHz 80MHz 10Vrms Power Frequency Magnetic Fields IEC 61000 4 8...

Страница 6: ...meters are specified at 25 C ambient and AC input unless otherwise indicated www DeltaPSU com July 2019 Rev 04 6 Block Diagram Device Description 1 Input terminal block connector 2 Output terminal blo...

Страница 7: ...Environment the device will run into Over Temperature Protection When activated power supply will latch off until the surrounding air temperature is lowered or the load is reduced as far as necessary...

Страница 8: ...ottom Each device is delivered ready to install Mounting No output power de rating across the entire input voltage range Dismounting Fig 2 1 Mounting Snap on the DIN rail as shown in Fig 2 1 1 Tilt th...

Страница 9: ...mm 0 39 inch to other units In case the adjacent device is a heat source the lateral distance will be 25mm 0 98 inch Note that the enclosure of the device can become very hot depending on the surround...

Страница 10: ...to 90 of its final steady state set value Hold up Time Time between the collapse of the AC input voltage and the output falling to 95 of its steady state set value Inrush Current Inrush current is the...

Страница 11: ...ernal feedback circuit fails The output voltage shall not exceed its specifications defined on Page 3 under Protections Power supply will latch off and require removal re application of input AC volta...

Страница 12: ...at any line voltage from 85 264Vac and set the PSU 1 and PSU 2 output voltage Step 2 Connect the power supply units PSU 1 and PSU 2 to Vin 1 Vin 2 respectively of the DRR 20N or 20A module shown on th...

Страница 13: ...tances in electrical and electronic equipment This product conforms to this standard Attention Delta provides all information in the datasheets on an AS IS basis and does not offer any kind of warrant...

Отзывы: