DFM-400P Rev 2.1 Installation and Appplication Guide  Edition 1.6 

Page 13 of 14

 

 

 

 

Cautions and Warnings 

 

WARNING

 

The DFM-400P Field Module is an Electro-statically sensitive device.  Proper ESD 

protection (ground strap) should be used when installing this product so that damage to the 
product does not occur. 

Compliance Declarations 

FCC Compliance Information 

This equipment has been tested and found to comply with the limits for a Class A digital device, 

pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection 

against harmful interference when the equipment is operated in a commercial environment. This 
equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in 

accordance with the instruction manual, may cause harmful interference to radio communications. 
Operation of this equipment in a residential area is likely to cause harmful interference in which 

case the user will be required to correct the interference at his own expense. 

 

Industry Canada Compliance Statement 

ICES-003   This Class A digital apparatus meets all requirements of the Canadian Interference-

Causing Equipment Regulations. 

 

Cet appareil numérique de la Classe A Respecte toutes les exigences du Règlement sur 

le matérial brouiller du Canada. 

 

UL Compliance Information 

 

 

This product conforms to the following UL requirements: 

 

UL916: Energy Management Equipment 

 

CAUTION – Risk of Electric Shock – More than one disconnect switch may 
be required to de-energize the equipment before servicing 

 

AVERTISSEMENT – Risque d'électrocution. Plus d'un interrupteur général 
peut être requis pour mettre l'équipement hors tension avant de procéder 

à son entretien 

 

All terminals are acceptable for Class 2 circuit connection only 

 

CAUTION – Input Class 2 Power Supplies are interconnected.  To Reduce 
the Risk of Fire or Electric Shock, Use only Class 2 sources Suitable for 

Interconnection 

 

AVERTISSEMENT – Les alimentations de classe 2 sont interconnectées. 

Pour réduire le risque d'incendie ou de décharge électrique, n'utiliser 
qu'une source d'alimentation de classe 2 adaptée 

 

Use Copper Conductor Only 

 

Select an external power supply that is certified for safety for the correct 

destination country and that has an output rating, which is considered an 
NEC Class 2 or Limited Power Source with the rating not to exceed 30 V 

rms, 42.4 V peak, 100 VA. 

 

Apply minimum 6.0 lb-in torque for tightening field wires into the terminal 

blocks. 

Содержание DFM-400P

Страница 1: ...al for electrical water gas and various flow meters the DFM 400P has four pulse inputs Two inputs support pulses from 0 to 200 Hz and the other two inputs support pulses from 0 to 2000 Hz Any addition...

Страница 2: ...Guide ORCAview Technical Reference Manual particularly Appendix G in the V3 22 Manual Important Information The Pulse Input Field Module is designed to work with Application Controller products starti...

Страница 3: ...Inputs 2 Pulse Inputs PP1 and PP2 0 2000 Hz each or actual maximum of about 1950 2 Pulse Inputs PP3 and PP4 0 200 Hz each Monitors either Dry Contact or Open Collector signals Jumper selectable DEBOUN...

Страница 4: ...DFM 400P Rev 2 1 Installation and Appplication Guide Edition 1 6 Page 4 of 14 Board Layout...

Страница 5: ...device is transmitting out the associated port and a red LED flashes to indicate when the device is receiving data through the port Jumpers DEBOUNCE DEBOUNCE Debounce circuitry which may be necessary...

Страница 6: ...ess from higher up devices may be enabled or disabled via jumper setting Enabled With the jumper in place the device automatically obtains portions of its overall BACnet device address as related to A...

Страница 7: ...ust be powered separately Network Cabling Requirements To ensure network stability and reliable communications particularly at high speeds on a BACnet RS 485 MS TP network it is imperative that you ad...

Страница 8: ...s that there is one other device configured as a System level device on the network 2 Pulse Input Field Modules Configured as LINKnet Devices Not applicable for the DFM 400P Field Module as it can onl...

Страница 9: ...Setup tab 60 AV4 PI1 Number of Sample Intervals Number of Intervals from PI Adv 5 AV5 PI1 Total Pulses Total Pulses from PI Data tab N A AV6 PI2 Converted Pulse Rate Pulse Value PI2 Present Value N A...

Страница 10: ...Input Field Module does not support this property There is no need when the hardware supports a jumper configurable debounce COV The PI objects each have a COV setting that is used globally for all of...

Страница 11: ...y the sample interval time and verify that the result remains within the Maximum Pulses per Sample Time as listed above Notice that only PP1 and PP2 are designed to handle the higher pulse rates In an...

Страница 12: ...ulse values MS TP Connection Objects All of the existing predefined DFM 400P objects are readily accessible over the MS TP network GCL Programming Write GCL programs in other controllers on the networ...

Страница 13: ...adian Interference Causing Equipment Regulations Cet appareil num rique de la Classe A Respecte toutes les exigences du R glement sur le mat rial brouiller du Canada UL Compliance Information This pro...

Страница 14: ...ns Class A EN 61000 3 2 1999 Power Line Harmonics Class D EN 61000 3 3 1998 Power Line Fluctuations Pst 1 Plt 0 65 EN50082 1 1997 Generic Immunity Standard Part 1 Residential EN 61000 4 2 1995 ESD Imm...

Отзывы: