background image

PROBLEM

16- ENG

D29382

Restricted, insufficient water
supply, or air in the water line.

Check supply hose, faucet, and
inlet screen.

Do not use water from a hot
water source, use water only from
a cold water faucet.

Excess noise

Water temperature is too high.

TROUBLE SHOOTING GUIDE

Motor will not
start and there
is no humming
sound

No or low
pressure

CAUSE

CORRECTION

Pressure washer not plugged in.

Plug in pressure washer.

“RESET” button on GFCI not
pushed.

Push “RESET” button.

Circuit breaker has tripped or fuse
is blown.

Reset breaker or replace fuse.

Too much load already on circuit.

Reduce load on circuit.

Try another 15 amp circuit.

Using an extension cord.

DO NOT use extension cords.

Supply voltage below required
minimum.

Check the voltage of the main
supply line.

Low water supply.

Water supply must be at least  5
GPM @ 20 psi.

High pressure hose is too long.

Use high pressure hose under
100 feet.

Power source
circuit
continues to
trip or blow
fuses

Motor hums but
will not start

Worn nozzle.

Replace nozzle.

Pressure
fluctuates with-
out opening gun

Water leak in high pressure fittings,
hose, or gun.

Replace hose or gun. If problem
continues take to authorized
service center.

Using an extension cord.

DO NOT use extension cords.

GFCI switch
indicator light
does not appear
after depressed

Circuit breaker has tripped or fuse
is blown.

Reset breaker or replace fuse. If
indicator light still does not
appear have receptacle checked
by a qualified electrician.

Unit does not
maintain steady
water pressure

Nozzle clogged

Clean nozzle, if unit still does not
maintain steady water pressure,
turn unit off and contact customer
service at 1-866-422-4286

Unit continues
to trip GFCI
switch

Nozzle clogged

Clean nozzle, if unit still does not
maintain steady water pressure,
turn unit off and contact customer
service at 1-866-422-4286

GFCI test fails

Circuit breaker has tripped or fuse
is blown.

Reset breaker or replace fuse. If
indicator light still does not
appear have receptacle checked
by a qualified electrician.

Содержание D29382

Страница 1: ...ore about DELTA MACHINERY visit our website at www deltamachinery com For Parts Service Warranty or other Assistance please call 1 866 422 4286 Electric Pressure Washer with 2400 Cleaning Units Model...

Страница 2: ...Instructions Do not use with extension cords SAFETY GUIDELINES DEFINITIONS Indicates an imminently hazardous situation which if not avoided will result in death or serious injury Indicates a potential...

Страница 3: ...ause injury or death Restricting any of the pressure washer ventilation openings will cause serious overheating and could cause fire Never place objects against or on top of pressure washer Operate pr...

Страница 4: ...ed while unit is running Know how to stop product and bleed pressure quickly Pressure washer pump contains moving parts Contact with moving parts can cause serious injury Never operate machine with pu...

Страница 5: ...e plug provided with the product if it will not fit the outlet have a proper outlet installed by a qualified electrician Do not use any type of adapter with this product EXTENSION CORDS Use additional...

Страница 6: ...e conveniently located and equipped to handle all in warranty and out of warranty service For the location of the nearest Authorized Warranty Service Center call 1 866 422 4286 24 hours a day 7 days a...

Страница 7: ...7 ENG D29382 ASSEMBLY INSTRUCTIONS 2 Connect spray wand to gun Tighten securely 3 Attach high pressure hose to gun Tighten securely 1 Place handle assembly onto frame and connect handle to frame...

Страница 8: ...ning solutions see How To Use Cleaning Solution Application Unit in this section READ THIS OWNER S MANUAL AND SAFETY RULES BEFORE OPERATING YOUR UNIT Compare the illustrations with your unit to famili...

Страница 9: ...change from narrow jet stream to fan jet as shown Total Stop System This unit is equipped with a total stop system When the trigger is released the motor is shut off automatically When the trigger is...

Страница 10: ...m cleaning solution application nozzle b Position the notch c on the pipe to the desired soap mixture 1 6 1 being the highest and 6 being the lowest c Press pipe into position 6 Fill application tank...

Страница 11: ...sures and velocities high enough to penetrate human and animal flesh which could result in amputation or other serious injury Leaks caused by loose fittings or worn or damaged hoses can result in inje...

Страница 12: ...ckwise until it snaps into place To remove nozzle turn nozzle counter clockwise to remove To connect chemical application unit c see How To Use Cleaning Solution Application Unit in this section 12 Tu...

Страница 13: ...detergent apply the high pressure jet keeping the nozzle at least 10 inches from the surface work from the bottom up SHUTTING DOWN YOUR PRESSURE WASHER 1 Place the ON OFF switch in the OFF position 2...

Страница 14: ...ction is removed 6 Direct water supply into nozzle end to backflush loosened particles for 30 seconds 7 Plug unit into appropriate outlet 8 Reassemble the nozzle to the wand Tighten securely to preven...

Страница 15: ...FOR MORE THAN 30 DAYS AND OR WHEN FREEZING TEMPERATURES ARE EXPECTED RV antifreeze needs to be run through the pump as outlined in the steps below 4 Obtain a funnel six ounces of RV antifreeze and app...

Страница 16: ...rce circuit continues to trip or blow fuses Motor hums but will not start Worn nozzle Replace nozzle Pressure fluctuates with out opening gun Water leak in high pressure fittings hose or gun Replace h...

Страница 17: ...17 ENG D29382...

Страница 18: ...with 60 and 80 gallon tanks will be inspected at the site of installation Contact the nearest Delta Authorized Warranty Service Center that provides on site service calls for service call arrangement...

Отзывы: