Chapter 12 Description of Parameter Settings
CP2000
12.1-06-21
temperature, overload output current and time. If overloads are not frequent, and the concern is
only about the carrier frequency operating with the rated current for a long time, and changes to
the carrier wave due to short overload are acceptable, set to 0.
Refer to the Section 9-7 “Derating Curve of Ambient Temperature” for the level of carrier
frequency. Take VFD007CP43A in normal duty for example, ambient temperature 50°C, UL
open-type, and independent installation. When the carrier frequency is set to 15 kHz, it
corresponds to 72% of the rated output current. When the output current is higher than the value,
it automatically decreases the carrier wave according to the ambient temperature, output current
and overload time. At this time, the overload capacity of the drive is still 120% of the rated
current.
Setting 1:
When the operating point exceeds derating curve 1, the carrier frequency is fixed to the set
value. Select this mode if the change of carrier wave and motor noise caused by ambient
temperature and frequent overload are not acceptable. Refer to Pr.00-17.
Refer to Section 9-7 “Derating Curve of Ambient Temperature” for the derating level of the rated
current. Take VFD007CP43A in normal duty for example, when the carrier frequency maintains
at 15 kHz, the rated current decreases to 72%. The oL protection executes when the current is
120%*72%=86% for one minute; therefore, it must operate by the curve to keep the carrier
frequency.
Setting 2:
The protection method and action are the same as setting it to 0, but this disables the current
limit when output current is the derating ratio x 160% of output current in normal load, and
derating ratio x 130% of output current in light load. The advantage is that this can provide a
higher starting output current when the carrier frequency setting is higher than the default. The
disadvantage is that the carrier wave derates easily when it overloads.
Use with settings for Pr.00-16 and Pr.00-17.
PT100 Voltage Level 1
Default: 5.000
Settings 0.000–10.000 V
PT100 Voltage Level 2
Default: 7.000
Settings 0.000–10.000 V
Condition settings: Pr. 06-57 > Pr.06-56.
PT100 Level 1 Frequency Protection
Default: 0.00
Settings 0.00–599.00 Hz
PT100 Activation Level 1 Protection Frequency Delay Time
Default: 60
Settings 0–6000 sec.
PT100 operation instructions:
(1) Use voltage type analog input (AVI1, AVI2 and ACI voltage 0–10V) and select PT100 mode.
Содержание CP2000 Series
Страница 3: ......
Страница 12: ...Chapter 1 Introduction CP2000 1 3 1 2 Model Name 1 3 Serial Number...
Страница 35: ...Chapter 1 Introduction CP2000 1 26 Digital Keypad KPC CC01 Figure 1 32...
Страница 36: ...Chapter 2 Installation CP2000 2 1 Chapter 2 Installation 2 1 Mounting Clearance 2 2 Flow and Power Dissipation...
Страница 42: ...Chapter 3 Unpacking CP2000 3 1 Chapter 3 Unpacking 3 1 Unpacking 3 2 The Lifting Hook...
Страница 72: ...Chapter 4 Wiring CP2000 4 1 Chapter 4 Wiring 4 1 System Wiring Diagram 4 2 Wiring...
Страница 77: ...Chapter 4 Wiring CP2000 4 6 Figure 4 5...
Страница 78: ...Chapter 4 Wiring CP2000 4 7 4 2 1 SINK NPN SOURCE PNP Mode Figure 4 6 Figure 4 7 Figure 4 8 Figure 4 9...
Страница 79: ...Chapter 4 Wiring CP2000 4 8 This page intentionally left bank...
Страница 109: ...Chapter 6 Control Terminals CP2000 6 12 This page intentionally left blank...
Страница 171: ...Chapter 7 Optional Accessories CP2000 7 62 EMC Filter Dimension EMC filter model name EMF021A23A EMF014A43A Figure 7 45...
Страница 172: ...Chapter 7 Optional Accessories CP2000 7 63 EMC filter model name EMF018A43A Figure 7 46...
Страница 173: ...Chapter 7 Optional Accessories CP2000 7 64 EMC filter model name EMF056A23A EMF039A43A Figure 7 47...
Страница 174: ...Chapter 7 Optional Accessories CP2000 7 65 EMC filter model name KMF370A KMF3100A Figure 7 48...
Страница 175: ...Chapter 7 Optional Accessories CP2000 7 66 EMC filter model name B84143D0150R127 Figure 7 49...
Страница 176: ...Chapter 7 Optional Accessories CP2000 7 67 EMC filter model name B84143D0200R127 Figure 7 50...
Страница 182: ...Chapter 7 Optional Accessories CP2000 7 73 Wall Mounting Embedded Mounting...
Страница 197: ...Chapter 7 Optional Accessories CP2000 7 88 6 Installation complete...
Страница 237: ...Chapter 7 Optional Accessories CP2000 7 128 This page intentionally left blank...
Страница 242: ...Chapter 8 Option Cards CP2000 8 5 Communication extension card Slot 1 CMC PD01 CMC DN01 CMC EIP01 EMC COP01 CMC PN01...
Страница 245: ...Chapter 8 Option Cards CP2000 8 8 I O Relay Card EMC D42A EMC D611A EMC R6AA EMC BPS01 EMC A22A...
Страница 247: ...Chapter 8 Option Cards CP2000 8 10 I O Relay Card EMC D42A EMC D611A EMC R6AA EMC BPS01 EMC A22A...
Страница 265: ...Chapter 8 Option Cards CP2000 8 28 This page intentionally left blank...
Страница 277: ...Chapter 09 Specifications CP2000 9 12 575V 690V Figure 9 3 Altitude Derating Curve Figure 9 4...
Страница 279: ...Chapter 09 Specifications CP2000 9 14 230V 460V Advanced Control Pr 00 11 2 PM SVC Pr 05 33 1 2 Figure 9 7 Figure 9 8...
Страница 281: ...Chapter 09 Specifications CP2000 9 16 9 8 Efficiency Curve Figure 9 11 Figure 9 12...
Страница 317: ...Chapter 10 Digital Keypad CP2000 10 36 This page intentionally left blank...
Страница 355: ...Chapter 11 Summary of Parameter Settings CP2000 11 38 11 Advanced Parameters Group 11 Advanced Parameters are reserved...
Страница 361: ...Chapter 11 Summary of Parameter Settings CP2000 11 44 This page intentionally left blank...
Страница 416: ...Chapter 12 Description of Parameter Settings CP2000 12 1 03 3 3 4 5...
Страница 417: ...Chapter 12 Description of Parameter Settings CP2000 12 1 03 4 6 7 8...
Страница 418: ...Chapter 12 Description of Parameter Settings CP2000 12 1 03 5 9 10 11...
Страница 419: ...Chapter 12 Description of Parameter Settings CP2000 12 1 03 6 12 13 14...
Страница 420: ...Chapter 12 Description of Parameter Settings CP2000 12 1 03 7 15 16 17...
Страница 421: ...Chapter 12 Description of Parameter Settings CP2000 12 1 03 8 18 19 20...
Страница 422: ...Chapter 12 Description of Parameter Settings CP2000 12 1 03 9 21 22 23...
Страница 423: ...Chapter 12 Description of Parameter Settings CP2000 12 1 03 10 24 25 26...
Страница 424: ...Chapter 12 Description of Parameter Settings CP2000 12 1 03 11 27 28 29...
Страница 425: ...Chapter 12 Description of Parameter Settings CP2000 12 1 03 12 30 31 32...
Страница 426: ...Chapter 12 Description of Parameter Settings CP2000 12 1 03 13 33 34 35...
Страница 427: ...Chapter 12 Description of Parameter Settings CP2000 12 1 03 14 36 37 38...
Страница 528: ...12 Description of Parameter Setting CP2000 12 1 11 1 11 Advanced Parameters Group 11 Advanced parameters are reserved...
Страница 560: ...Chapter 12 Description of Parameter Settings CP2000 12 2 00 6 III PM SVC Carrier Start up Adjustment...
Страница 835: ...Chapter 16 PLC Function Applications CP2000 16 152 Step 3 Physical configuration CP2000 Step 4 Write to PLC program...
Страница 836: ...Chapter 16 PLC Function Applications CP2000 16 153...
Страница 838: ...Chapter 16 PLC Function Applications CP2000 16 155...
Страница 841: ...Chapter 16 PLC Function Applications CP2000 16 158 This page intentionally left blank...
Страница 857: ...Chapter 17 Introduction to BACnet CP2000 17 16 This page intentionally left blank...