13
5.3 Initial lubrication
The following lubrication guidelines must be carried out before the electric winch is put into use. (or
use an equivalent.)
Model
DPS.200
DPS.250
DPS.300
DPS.500
DPT.30075
Lifting capacity (kg)
200
250
300
500
300
Duty Cycle
40%
Voltage (v)
230
230
230
230
400
IP rating
44
44
44
44
44
Lubricant of gearbox
Recommended SHELL Gadus S3 V220C 2 grease or equilavant
Lubricant quantity gearbox
0.5 lt
0.5 lt
0.5 lt
0.75 lt
0.5 lt
Lubrication period
6 months or 240 working hours
Lubricant of wire rope
Recommended SAE 30 motor oil or equilavant
Lubrication
Heavy Service: daily / Normal: weekly / Infrequent: Monthly
Model
DPT.30151
DPT.30375
DPT.30750
DPT.31500
DPT.34000
Lifting capacity (kg)
500
1000
2000
3000
5000
Duty Cycle
40%
Voltage (v)
400
IP rating
44
54
54
54
54
Lubricant of gearbox
Recommended SHELL Gadus S3 V220C 2 grease or equilavant
Lubricant quantity gearbox
0.75 lt
2.3 lt
3 lt
3 lt
3 lt
Lubrication period
6 months or 240 working hours
Lubricant of wire rope
Recommended SAE 30 motor oil or equilavant
Lubrication
Heavy Service: daily / Normal: weekly / Infrequent: Monthly
5.4 Connection to electrical supply
An adequate electricity supply system is required along the total length of travel(where appropriate).
The supply voltage and frequency at which the winch operates is marked on the motor rating plate. It
is Imperative to check before connecting the unit that these figures correspond with those of the
supply voltage.
5.5 Starting
When installation is completed, the following procedure should be carried out:
1.
Isolate the power supply.
2.
Check that all mechanical and electrical joints and connections are tight and secure.
3.
Switch on power supply.
4.
Operate the
electric winch and check that the operation is smooth at all times.
5.
Check the brake, under light and full load conditions.
6
Always check the correct functioning of the emergency stop.
DANGER
Emergency procedure:
In the event of a blocked steel wire or any other
malfunction of
electric pulling winch, immediately stop the maneuverer
without attempting any further actions. Immediately set up a safety perimeter
around the winch and the load to prevent access by any unauthorized persons.
Call in the necessary personnel to remove the load and intervene on the winch.
Содержание CP.0.DPS Series
Страница 8: ...8 3 2 2 electric pulling winch capacity per layer ...
Страница 21: ...21 CP 0 DPS 200 Control Circuit ...
Страница 23: ...23 CP 0 DPS 250 Control Circuit ...
Страница 25: ...25 CP 0 DPS 300 Control Circuit ...
Страница 27: ...27 CP 0 DPS 500 Control Circuit ...
Страница 29: ...29 CP 0 DPT 30075 Control Circuit ...
Страница 31: ...31 CP 0 DPT 30151 Control Circuit ...
Страница 33: ...33 CP 0 DPT 30375 Control Circuit ...
Страница 35: ...35 CP 0 DPT 30750 Control Circuit ...
Страница 37: ...37 CP 0 DPT 31500 Control Circuit ...
Страница 39: ...39 CP 0 DPT 34000 Control Circuit ...
Страница 40: ...40 9 Derived certificate of test Declaration of CE conformity ...