background image

1.

DANGER: DO NOT USE THIS UNIT TO FILTER METAL DUST.

Combining wood and metal dust can create

an explosion or fire hazard. This unit is intended to filter non-explosive atmospheres only.

2.

WARNING: DUST GENERATED BY CERTAIN WOODS AND WOOD PRODUCTS CAN BE HAZARDOUS

TO YOUR HEALTH.

3.

WARNING: DO NOT USE THIS UNIT TO DISSIPATE FUMES OR SMOKE

This air cleaner is intended for use

where only dry airborne dust is present. Its use should be limited to non-explosive, non-metallic atmospheres.

4

. DO NOT OPERATE THIS UNIT UNTIL IT IS COMPLETELY ASSEMBLED AND INSTALLED ACCORDING TO

THE INSTRUCTIONS

.

5.

OBTAIN ADVICE FROM YOUR SUPERVISOR, INSTRUCTOR, OR ANOTHER QUALIFIED PERSON 

if you are

not thoroughly familiar with the operation of this unit.

6.

FOLLOW ALL WIRING CODES

and recommended electrical connections.

7.

DO NOT LIFT THIS UNIT BY THE POWER CORD. 

Do not use the power cord as a hanging device.

8.

SECURELY ANCHOR THIS UNIT INTO A SUPPORTING STRUCTURE 

when suspending it from the ceiling.

Always keep a minimum of 7 feet between the bottom of the unit and the floor surface to allow for sufficient head
clearance. Use only chain rated for a minimum of 150 lb. working load to adequately hold the unit. Use steel S-
Hooks that are at least 1/4" in diameter to suspend the unit from the ceiling. Lag-type bolts used to suspend the
unit from the ceiling must be threaded at least 1-1/2" into supporting structural members.

9.

SUPPORT THIS UNIT OR SECURELY CLAMP IT TO THE WORK SURFACE WHEN IT IS USED IN A PORTABLE
APPLICATION

to eliminate potential movement and/or damage from falling.

10.

INSURE THAT THE INTAKE AND EXHAUST AREAS ARE CLEAR PRIOR TO STARTING THE UNIT.

11.

KEEP ARMS, HANDS, AND FINGERS AWAY FROM THE FAN. 

Avoid all exposure to rotating parts.

12.

DO NOT OPERATE THIS UNIT WITHOUT THE FILTERS IN PLACE.

13.

DO NOT ATTEMPT TO REMOVE OR REPLACE THE FILTER(S) WHILE THE UNIT IS RUNNING.

Make certain

that the unit is disconnected from the power source.

14.

MAINTAIN THE UNIT IN TOP CONDITION

. Keep filters clean for optimum performance. Follow all instructions for

changing and cleaning filters.

15.

STORE THIS UNIT IN A LOCATION

that eliminates the potential of damage to the power cord. Safely store power

cord on the unit to eliminate tripping hazards.

16

. TURN THE UNIT “OFF” AND DISCONNECT IT FROM THE POWER SOURCE

before installing or removing

accessories, or when making repairs.

3

SAFETY RULES FOR

AIR CLEANERS

READ AND SAVE THESE INSTRUCTIONS

.

Refer to them often

and use them to instruct others

.

Содержание 50-870

Страница 1: ...651 0001 03 31 02 Copyright 2002 Delta Machinery ESPA OL P GINA 11 To learn more about DELTA MACHINERY visit our website at www deltamachinery com For Parts Service Warranty or other Assistance pleas...

Страница 2: ...mends that this machine not be modified and or used for any application other than that for which it was designed If you have any ques tions relative to a particular application DO NOT use the machine...

Страница 3: ...f 150 lb working load to adequately hold the unit Use steel S Hooks that are at least 1 4 in diameter to suspend the unit from the ceiling Lag type bolts used to suspend the unit from the ceiling must...

Страница 4: ...is shipped complete in one shipping container Carefully unpack the Air Cleaner and all loose items from the shipping container WARNING DO NOT LIFT THE AIR CLEANER BY POWER CORD Fig 2A illustrates the...

Страница 5: ...FLOOR SURFACE 1 Locate four 4 self adhesive rubber feet A Fig 3 supplied with the unit Carefully place the air cleaner on a firm supporting surface with access to the bottom of the cabinet Fig 3 Appl...

Страница 6: ...rame or other non structural members 6 Fig 5 Fig 6 MOUNTING THE AIR CLEANER TO THE CEILING OR OVERHEAD SUPPORT WARNING Keep a minimum of seven feet between bottom of air cleaner and the floor surface...

Страница 7: ...ED IF YOU ARE NOT SURE HAVE A QUALIFIED ELECTRICIAN CHECK THE RECEPTA CLE 1 A l l g ro u n d e d c o rd c o n n e c t e d t o o l s In the event of a malfunction or breakdown grounding provides a path...

Страница 8: ...accept the tool s plug When using an extension cord be sure to use one heavy enough to carry the current of the saw An undersized cord will cause a drop in line voltage resulting in loss of power and...

Страница 9: ...eplaced Delta Catalog 50 822 or cleaned depending on its condition Clean this filter in one of two methods use a shop vac to remove the dust or use compressed air 30 psi maxi mum to blow the dust out...

Страница 10: ...exclusive remedy with respect to defective products all other war ranties express or implied whether of merchantability fitness for purpose or otherwise are expressly disclaimed by Delta Delta Buildi...

Страница 11: ...357 9762 Fax 510 357 7939 FLORIDA Davie 33314 Miami 4343 South State Rd 7 441 Unit 107 Phone 954 321 6635 Fax 954 321 6638 Tampa 33609 4538 W Kennedy Boulevard Phone 813 877 9585 Fax 813 289 7948 GEOR...