TECHNICAL DATASHEET

 

PMT Panel Mount Power Supply 

36V 350W 1 Phase / PMT-36V350W1A

□ 

 

 

  

All parameters are specified at 25°C ambient and AC input unless otherwise indicated.

 

  

www.DeltaPSU.com (April 2015, Rev. 01)

  

 

3

 

Environment 

 

Surrounding Air Temperature

 

Operating  -10°C to +70°C

 

 

Storage  -25°C to +85°C

 

Power De-rating

 

  > 50°C de-rate power by 2.5% / °C 

< 100Vac de-rate power by 3% / V 

< 200Vac de-rate power by 3% / V 

Operating Humidity

 

  5 to 95% RH (Non-Condensing)

 

Operating Altitude

 

  0 to 5,000 Meters

 

Shock Test (Non-Operating)

 

  IEC 60068-2-27, Half Sine: 50G for a duration of 11ms, 

3 times per direction, 18 times in total

 

Vibration 

Operating 

IEC 60068-2-6, Sine Wave: 10Hz to 150Hz @ 25m/S² 

(2.5G peak); 90 min per axis for all X, Y, Z direction 

 

Non-Operating 

IEC 60068-2-6, Random: 5Hz to 500Hz @ 2.09Grms 

peak; 20 min per axis for all X, Y, Z direction 

Pollution Degree 

  2 

 

 

Protections 

 

Overvoltage

 

41.4V~48.6V, Latch Mode

 

Overload / Overcurrent

 

105%

~150%

 of rated load current, Hiccup Mode,  

Non-Latching (Auto-Recovery) 

Over Temperature

 

Hiccup Mode, Non-Latching 

(Auto-Recovery when the fault is removed) 

Short Circuit

 

Hiccup Mode, Non-Latching 

(Auto-Recovery when the fault is removed)

 

Protection Against Shock

 

Class I with PE* connection

 

*PE: Primary Earth 

 

 

Reliability Data 

 

MTBF 

> 700,000 hrs. as per Telcordia SR-332 

I/P: 100Vac, O/P: 100% load, Ta: 35

°

Expected Cap Life Time

 

 

10 years (115Vac & 230Vac, 50% load @ 40°C)

 

 

 

Safety Standards / Directives 

 

Electrical Safety 

  TUV Bauart to EN 60950-1, UL/cUL recognized to  

UL 60950-1 and CSA C22.2 No. 60950-1 (File No. 

E131881), CB scheme to IEC 60950-1

 

CE 

  In conformance with EMC Directive 2004/108/EC and 

Low Voltage Directive 2006/95/EC 

Material and Parts

 

  RoHS Directive 2011/65/EU Compliant

 

Galvanic Isolation

 

Input to Output  3.0KVac

 

 

Input to Ground  1.5KVac

 

 

Output to Ground  0.5KVac

 

 

 

 

 

Содержание 36V350W1AR

Страница 1: ...age of 36V with a wide operating temperature range from 10 C to 70 C and can withstand shock and vibration in accordance to IEC 60068 2 27 and IEC 60068 2 6 respectively In addition to features like o...

Страница 2: ...A 240Vac Output Ratings Characteristics Nominal Output Voltage 36Vdc Output Voltage Tolerance 1 initial set point tolerance from factory Output Voltage Adjustment Range 32 4 39 6Vdc Output Current 9 7...

Страница 3: ...er axis for all X Y Z direction Pollution Degree 2 Protections Overvoltage 41 4V 48 6V Latch Mode Overload Overcurrent 105 150 of rated load current Hiccup Mode Non Latching Auto Recovery Over Tempera...

Страница 4: ...ransient Burst IEC 61000 4 4 Level 3 Criteria A1 2kV Surge IEC 61000 4 5 Level 3 Criteria A 1 Common Mode 2 2kV Differential Mode 3 1kV Conducted IEC 61000 4 6 Level 3 Criteria A 1 150kHz 80MHz 10Vrms...

Страница 5: ...at 25 C ambient and AC input unless otherwise indicated www DeltaPSU com April 2015 Rev 01 5 Block Diagram Device Description 1 Input Output terminal block connector 2 DC voltage adjustment potentiome...

Страница 6: ...Power Supply 36V 350W 1 Phase PMT 36V350W1A All parameters are specified at 25 C ambient and AC input unless otherwise indicated www DeltaPSU com April 2015 Rev 01 6 Dimensions L x W x D 215 x 115 x...

Страница 7: ...l Mount Power Supply 36V 350W 1 Phase PMT 36V350W1A All parameters are specified at 25 C ambient and AC input unless otherwise indicated www DeltaPSU com April 2015 Rev 01 7 L x W x D 215 x 115 x 50 m...

Страница 8: ...ltage will go into bouncing mode and will recover when the surrounding air temperature is lowered or the load is reduced as far as necessary to keep the device in working condition 3 In order for the...

Страница 9: ...ounting Orientation Use flexible cable stranded or solid of AWG No 22 12 The input output connectors allowable current is 23A max per pin User should calculate and select the suitable wire specificati...

Страница 10: ...er supply Do not touch the device while it is in operation or immediately after power is turned OFF Risk of burning Do not touch the terminals while power is being supplied Risk of electric shock Prev...

Страница 11: ...a certain period of time The time required for the output to reach 95 of its set value after the input voltage is removed Graph illustrating the Start up Time Rise Time and Hold up Time Inrush Curren...

Страница 12: ...U Short Circuit Protection The power supply s output OLP OCP function also provides protection against short circuits When a short circuit is applied the output current will operate in Hiccup mode as...

Страница 13: ...ut from DRR module will be VO output voltage of power supply Vdrop in DRR module Parallel Operation These DRR modules can also be used for Parallel function in order to increase the output power by N...

Страница 14: ...striction of the usage of hazardous substances The European directive 2011 65 EU limits the maximum impurity level of homogeneous materials such as lead mercury cadmium chrome polybrominated flame ret...

Отзывы: