background image

TECHNICAL DATASHEET

 

PMT Panel Mount Power Supply 

36V 350W 1 Phase / PMT-36V350W1A

□ 

 

 

  

All parameters are specified at 25°C ambient and AC input unless otherwise indicated.

 

  

www.DeltaPSU.com (April 2015, Rev. 01)

  

 

11

 

Functions 

Start-up Time 

The time required for the output voltage to reach 90% of its set value, after the input voltage is applied. 

 

 

Rise Time 

The time required for the output voltage to change from 10% to 90% of its set value. 

 

 

Hold-up Time 

Hold up time is the time when the AC input collapses and output voltage retains regulation for a certain period of time. The time 

required for the output to reach 95% of its set value, after the input voltage is removed. 

 

 

 

Graph illustrating the Start-up Time, Rise Time, and Hold-up Time 

 

 
Inrush Current 

Inrush current is the peak, instantaneous, input current measured 

and, occurs when the input voltage is first applied. For AC input 

voltages, the maximum peak value of inrush current will occur 

during the first half cycle of the applied AC voltage. This peak 

value decreases exponentially during subsequent cycles of AC 

voltage. 

 

 

 

 

 

 

Dynamic Response 

The power supply output voltage will remain within ±5  of its 

steady state value, when subjected to a dynamic load from 10 to 

50% and 50 to 100% of its rated current. 

 

  10 to 50% Load 

 

 

  50 to 100% Load 

 

 

Содержание 36V350W1AR

Страница 1: ...age of 36V with a wide operating temperature range from 10 C to 70 C and can withstand shock and vibration in accordance to IEC 60068 2 27 and IEC 60068 2 6 respectively In addition to features like o...

Страница 2: ...A 240Vac Output Ratings Characteristics Nominal Output Voltage 36Vdc Output Voltage Tolerance 1 initial set point tolerance from factory Output Voltage Adjustment Range 32 4 39 6Vdc Output Current 9 7...

Страница 3: ...er axis for all X Y Z direction Pollution Degree 2 Protections Overvoltage 41 4V 48 6V Latch Mode Overload Overcurrent 105 150 of rated load current Hiccup Mode Non Latching Auto Recovery Over Tempera...

Страница 4: ...ransient Burst IEC 61000 4 4 Level 3 Criteria A1 2kV Surge IEC 61000 4 5 Level 3 Criteria A 1 Common Mode 2 2kV Differential Mode 3 1kV Conducted IEC 61000 4 6 Level 3 Criteria A 1 150kHz 80MHz 10Vrms...

Страница 5: ...at 25 C ambient and AC input unless otherwise indicated www DeltaPSU com April 2015 Rev 01 5 Block Diagram Device Description 1 Input Output terminal block connector 2 DC voltage adjustment potentiome...

Страница 6: ...Power Supply 36V 350W 1 Phase PMT 36V350W1A All parameters are specified at 25 C ambient and AC input unless otherwise indicated www DeltaPSU com April 2015 Rev 01 6 Dimensions L x W x D 215 x 115 x...

Страница 7: ...l Mount Power Supply 36V 350W 1 Phase PMT 36V350W1A All parameters are specified at 25 C ambient and AC input unless otherwise indicated www DeltaPSU com April 2015 Rev 01 7 L x W x D 215 x 115 x 50 m...

Страница 8: ...ltage will go into bouncing mode and will recover when the surrounding air temperature is lowered or the load is reduced as far as necessary to keep the device in working condition 3 In order for the...

Страница 9: ...ounting Orientation Use flexible cable stranded or solid of AWG No 22 12 The input output connectors allowable current is 23A max per pin User should calculate and select the suitable wire specificati...

Страница 10: ...er supply Do not touch the device while it is in operation or immediately after power is turned OFF Risk of burning Do not touch the terminals while power is being supplied Risk of electric shock Prev...

Страница 11: ...a certain period of time The time required for the output to reach 95 of its set value after the input voltage is removed Graph illustrating the Start up Time Rise Time and Hold up Time Inrush Curren...

Страница 12: ...U Short Circuit Protection The power supply s output OLP OCP function also provides protection against short circuits When a short circuit is applied the output current will operate in Hiccup mode as...

Страница 13: ...ut from DRR module will be VO output voltage of power supply Vdrop in DRR module Parallel Operation These DRR modules can also be used for Parallel function in order to increase the output power by N...

Страница 14: ...striction of the usage of hazardous substances The European directive 2011 65 EU limits the maximum impurity level of homogeneous materials such as lead mercury cadmium chrome polybrominated flame ret...

Отзывы: