16
button to select the "Turbo" option and then pressing the Enter/Cancel button.
Turbo function setting is as shown in Fig.19:
Unit On, no Turbo function
Press “Function” button to set
turbo function
Press “Enter/Cancel” button to
activate turbo function
Press “Function” button to set
turbo function
Press “Enter/Cancel” button to
cancel turbo function
Fig.19 Turbo Function Setting
Notes:
① .
The Turbo function will not be deactivated due to power failure. In DRY, FAN and AUTO
modes, the Turbo function is unavailable and the function symbol won’t be displayed.
② .
The Turbo function will be automatically deactivated as the Quiet function is activated.
③ .
The FAN button can also be used to adjust Turbo function.
3.14 SAVE Function Setting
Energy Saving Function: Energy saving can make the air conditioner runs in a smaller
temperature range by setting lower limited value of setting temperature in the COOL or DRY mode
and upper limited value in the HEAT mode.
(1). Energy Saving Setting for Cooling
When the unit runs under the COOL or DRY mode, press the Function button to select the
“SAVE” function option, with “SAVE” flashing, and then press ▲ or ▼ to adjust the lower limit, after
that, press the Enter/Cancel button to activate this function.
(2). Energy Saving Setting for Heating
When the unit runs under the HEAT mode, press the Function button to select the “SAVE”
function option, with “SAVING” flashing, then press the Mode button to switch to the “SAVE” setting
for the HEAT mode and then press ▲ or ▼ to adjust the upper limit, after that, press the Enter/