13
3.4.7
Air Exchange Setting
*
Turn on air Exchange function:
Under on-state of the unit, press
Function
button to go to the this function setting (
Air
mark blinks).AIR 1 displayed
at the ambient temperature-displayed location (888) is defaulted (the last type of
AIR
will be displayed after
adjustment).Press
▲
or
▼
button to adjust air type. Press
Enter/Cancel
button to turn on/off air function. After
turning on this function, the air mark shows.
There are 10 types of AIR, but only 1-2 types are for remote control. Refer to the following details:
1
――
The unit continuously runs for 60min, and fresh air valve runs for 6 min.
2
――
The unit continuously runs for 60min, and fresh air valve runs for 12 min.
3
――
The unit continuously runs for 60min, and fresh air valve runs for 18 min.
4
――
The unit continuously runs for 60min, and fresh air valve runs for 2 4 min.
5
――
The unit continuously runs for 60min, and fresh air valve runs for 30 min.
6
――
The unit continuously runs for 60min, and fresh air valve runs for 36 min.
7
――
The unit continuously runs for 60min, and fresh air valve runs for 42 min.
8
――
The unit continuously runs for 60min, and fresh air valve runs for 48 min.
9
――
The unit continuously runs for 60min, and fresh air valve runs for 54 min.
10
――
The unit continuously runs for 60min, and fresh air valve always runs.
Turn off air Exchange function: During Air function, press
Function
button to go to the Air function. In this case,
air
mark is blinking, and then press
Enter/cancel
button to turn off this function. Air mark will subsequently disappear.
Air Exchange setting is shown as in fig.3.4.7:
Fig.3.4.7
Air
exchange
device
Note: In air exchange mode, press
Function
button or there is not any operation within 5s after the last button
operation, the system will be quit from
air exchange
setting and current energy-saving data won’t be
memorized.
Содержание 21CK018C24
Страница 3: ...2 1 Names and functions of parts ...
Страница 31: ...30 8 Optimum operation ...
Страница 33: ...32 The following are not troubles ...
Страница 34: ...33 10 Installation notes ...
Страница 35: ...34 11 Care and maintenance Please pull out the power plug after you used the air conditioner ...
Страница 36: ...35 ...
Страница 37: ...36 ...
Страница 38: ...37 The operation in detach and fix the flap is not including the 18K type ...
Страница 49: ...48 Fig 8 butted terminals Fig 9 ...
Страница 63: ......
Страница 64: ...Thank you for Choosing airconditioners Perfectly engineered for your comfort www delta dct com ...