ACC-8F & ACC-8FP
Delta Tau Data Systems, Inc.
Connectors and Jumpers
18
P3 DB9-pin Connector
6
9
1
5
Top View
Pin #
Symbol
Function
Description
Notes
1
USER1
Input
General Capture Flag
Sinking or sourcing
2
MLIM1
Input
Negative Limit Flag
Sinking or sourcing
3
FL_RT1
Input
Return For All Flags
+V (12 To 24 V) Or 0 V
4
FLGRET
Output
Flag Return
12/25 V Rreturn from TB3
5
AGND
Ground
Analog Common
6
PLIM1
Input
Positive Limit Flag
Sinking or sourcing
7
HOME1
Input
Home Flag
Sinking or sourcing
8
FLGPWR
Output
Flag Power
+ 12/25 V from TB3
9
AGND
Ground
Analog Common
A DB 9 connector for connection to main flags of the 1
st
channel (home, limits, & user). This connector
provides alternate connection for the standard machine input flags for an axis. The USER flag can also be
brought in on J4 or TB4.
P4 DB9-pin Connector
6
9
1
5
Top View
Pin #
Symbol
Function
Description
Notes
1
USER2
Input
General Capture Flag
Sinking or sourcing
2
MLIM2
Input
Negative Limit Flag
Sinking or sourcing
3
FL_RT2
Input
Return For All Flags
+V (12 to 24 V) or 0 V
4
FLGRET
Output
Flag Return
12/25 V return from TB3
5
AGND
Ground
Analog Common
6
PLIM2
Input
Positive Limit Flag
Sinking or sourcing
7
HOME2
Input
Home Flag
Sinking or sourcing
8
FLGPWR
Output
Flag Power
+ 12/25 V From TB3
9
AGND
Ground
Analog Common
A DB 9 connector for connection to main flags of the 2
nd
channel (home, limits, & user). This connector
provides alternate connection for the standard machine input flags for an axis. The USER flag can also be
brought in on J4 or TB5.
Содержание 8F
Страница 2: ......
Страница 4: ...ACC 8F ACC 8FP Delta Tau Data Systems Inc Contents ii...
Страница 8: ...ACC 8F ACC 8FP Delta Tau Data Systems Inc Introduction 4...
Страница 9: ...Delta Tau Data Systems Inc ACC 8F ACC 8FP Board Layout 5 BOARD LAYOUT ACC 8F Layout...
Страница 10: ...ACC 8F ACC 8FP Delta Tau Data Systems Inc Board Layout 6 ACC 8FP Layout...