MACRO-CPU Hardware Reference
HARDWARE RE-INITIALIZATION
MACRO hardware reinitialization to factory defaults is enabled when the SW1 setting is set to 15 or F
(hexidecimal) and the power is cycled at the MACRO Station. The only time the user would want to use a
hardware reinitialization to factory defaults with the MACRO Station would be if the MACRO Station always
powers up with a watchdog (typically if the ring clock at the Ultralite is different than the ring clock at the
MACRO Station).
Node 11
will be the only MACRO Station node enabled. Therefore the user will have to enable
node 11 of the MACRO IC at the Ultralite to communicate to the MACRO Station.
Ultralite Example
: Servo nodes 0,1,4,5 enabled at Ultralite (I996=$0F8033)
(A) The user would have to enable node 11, I996=$0F8833
(B) Then user can reistablish communications with MS11,(MIvar) commands
(C) Issue MS$$$***11 to ensure re-initialization
(D) Issue MSSAVE11 command to save the factory defaults to the Station
Turbo Ultralite Example
: Servo nodes 0,1,4,5 enabled at Ultralite (I6841=$0F8033)
(A) The user would have to enable node 11, I996=$0F8833
(B) Then user can reistablish communications with MS11,(MIvar) commands
(C) Issue MS$$$***11 to ensure re-initialization
(D) Issue MSSAVE11 command to save the factory defaults to the Station
Hardware Re-initialization
18
Содержание 3A0-602804-10x
Страница 2: ......
Страница 4: ...MACRO CPU Hardware Reference U MACRO CPU HARDWARE MEMORY MAP 28 ACCESSORIES 30 ii Contents...
Страница 10: ...MACRO CPU Hardware Reference 3U MACRO CPU Configuration 6...
Страница 14: ...MACRO CPU Hardware Reference 3U MACRO CPU Board Hardware Setup 10...
Страница 23: ...MACRO CPU Hardware Reference Hardware Re initialization 19...
Страница 25: ...MACRO CPU Hardware Reference Firmware Updates 21...
Страница 33: ...MACRO CPU Hardware Reference U MACRO CPU Hardware Memory Map 29...