Model

ESB4-SXI-100

ESB4-SXI-70

ESB4-SXI-50

Input Voltage

14.4V

10.8V

Speed (RPM)

0~2000

0~2600

0~1900

Impacts (BPM)

0~2600

0~3400

0~2500

Torque

20~100 Nm

14.7~73.7 ftlb

20~70 Nm

14.7~51.6 ftlb

5~50 Nm

3.7~36.9 ftlb

Approximate

Torque Output 

based on 

Fastener Size 

(using force 

setting below)

M10 M12 M14 M16

M8

M10 M10 M12

M6

M8

M10 M12

Nm

8

|

40

Nm

20

|

70

Nm

20

|

90

Nm

28

|

100

Nm

8

|

30

Nm

8

|

40

Nm

20

|

60

Nm

20

|

70

Nm

3

|

20

Nm

3

|

20

Nm

5

|

30

Nm

12

|

50

ftlb

5.9

|

29.5

ftlb

14.7

|

51.6

ftlb

14.7

|

66.3

ftlb

20.6

|

73.7

ftlb

5.9

|

22.1

ftlb

5.9

|

29.5

ftlb

14.7

|

44.2

ftlb

14.7

|

51.6

ftlb

2.2

|

14.7

ftlb

2.2

|

14.7

ftlb

3.7

|

22.1

ftlb

8.8

|

36.8

Force Setting

F06

F03

Weight

Less Battery

1.02 kg /2.2 lbs

1.0 kg / 2.2 lbs

Duty Cycle

1.0 sec ON ~ 3.0 sec OFF

Dimensions

(L x H) 

Less Battery

174mm x 202mm

6.8 in x 7.9 in

Battery

SKC-LB1425

SKC-LB1025M

Charger

ESB-CHG70

ESB-CHG50XA

Remote Control

DR-IRC1

Curve Chart

Содержание ESB4-SXI Series

Страница 1: ...eries Automatic Shut off Precision Impact Driver USER MANUAL Delta Regis Tools Inc 7370 Commercial Circle Fort Pierce FL 34951 sales deltaregis com 1 888 500 2755 www deltaregis com Delta Regis_ESB4 S...

Страница 2: ......

Страница 3: ...s 5 Operating Instructions 5 Operating Function Summary 7 Function Description 10 1 Main panel buttons and screen display instructions 10 2 DR IRC1 Remote control overview 11 3 Operation function sett...

Страница 4: ...cated to avoid danger 3 When the device is not in use remove the battery and store it in a dry and safe place 4 Please carefully set the device to appropriate torque according to the requirements of t...

Страница 5: ...stall protection Low battery protection Forward and reverse three stage control protection Device sleep function if tool is unused for 3 min Operating Instructions 1 Before using this device please f...

Страница 6: ...attached Please see table below DEVICE STATE ACTION FEEDBACK INCORRECT CORRECT Tool in active mode Press the trigger to exit sleep mode Indicator Lights Alternately flash red and green Green will fla...

Страница 7: ...ierce FL 34951 772 465 4302 7 Operating Function Summary No Description 1 Trigger 2 Forward Reverse Switch 3 LED Work light 4 Bit Socket Holder 5 Aluminum Alloy Cover 6 Belt Hook Mount 7 Signal Displa...

Страница 8: ...e counter clockwise Whenever the device is not in use leave the forward and reverse switch lever in the middle position Leave the forward and reverse switch lever in the middle position and press the...

Страница 9: ...ot change the forward and reverse switch lever to avoid system error detection The mechanical wear of the device depends on the user s torque time or frequency The greater the torque the longer the ti...

Страница 10: ...Quickly browse the setting of the running program Press and hold the button to enter the remote control setup mode Pc Button Quickly switch the running program Remember After switching programs press...

Страница 11: ...mode display screen on the device will read SEr Program Choose Program P01 P05 1 Scroll through program with buttons Once on desired program you can select additional functions to add into specific p...

Страница 12: ...h programs and add to sequence with button if desired Programs that were added to sequence will continue to cycle through in the order they were selected For example if you select P 0 1 and P 0 2 once...

Страница 13: ...99 fas teners depending on application needs 2 Choose n0F only if you intend to turn off the screw count on the display Force Impact Force Setting Allows you to adjust the hammer strength based on app...

Страница 14: ...OFF Once in secondary functions menu press the button on remote to toggle NG Confirm alert ON or OFF NG Confirm ON NG Confirm OFF OK All Confirm ON OFF Once in secondary functions menu press the butto...

Страница 15: ...eased Stripped Screw If device drive continues to spin outside of normal parameters Red Light ON Top Continuous short beep until trigger is released Sleep Mode If device is unused for 180 sec sleep mo...

Страница 16: ...ch is downward then push the device into the cover until it clips in 7 For testing this device it is recommended to use our company s specified testing equipment 8 This screwdriver is of clutch type m...

Страница 17: ...b F02 H01 50 12 45 Nm 8 8 33 1 ftlb F01 H01 99 20 50 Nm 14 7 36 9 ftlb F01 H01 99 20 65 Nm 14 7 47 9 ftlb F01 H01 50 8 35 Nm 5 9 25 8 ftlb Weight Less Battery 1 02 kg 2 2 lbs 1 0 kg 2 2 lbs Recommende...

Страница 18: ...M10 M12 M14 M16 M8 M10 M10 M12 M6 M8 M10 M12 Nm 8 40 Nm 20 70 Nm 20 90 Nm 28 100 Nm 8 30 Nm 8 40 Nm 20 60 Nm 20 70 Nm 3 20 Nm 3 20 Nm 5 30 Nm 12 50 ftlb 5 9 29 5 ftlb 14 7 51 6 ftlb 14 7 66 3 ftlb 20...

Страница 19: ......

Страница 20: ...www deltaregis com sales deltaregis com 7370 Commercial Circle Fort Pierce FL 34951 772 465 4302 20 ESB4 SXI Series...

Отзывы: