www.deltaregis.com
7370 Commercial Circle
Fort Pierce, FL 34951
(
772.465.4302
13
Save
Save Function:
1) After parameters are set, press the save button to
save settings and exit the setup function. Tool display
will return to the main screen.
2) After parameters are set, Device will not run for 30
seconds and will save settings automatically. Device will
automatically return to the main screen.
3) Once device has returned to main screen press the
“Res” button on the device to update batch count with
updated settings.
Batch
Count
Batch Count Setting:
1) Batch count can be set from [n0F] & [n01]~[n99] fas-
teners depending on application needs.
2) Choose [n0F] only if you intend to turn off the screw
count on the display.
Force
Impact Force Setting: Allows you to adjust the hammer
strength based on application needs.
ESB4-SXI-100 has force settings of 1~6
ESB4-SXI-70 has force settings of 1~6
ESB4-SXI-50 has force settings of 1~3
Impacts
Impact Fine-tune Setting:
1) Impacts can be fine-tuned from [H0F] & [H01]~[H99]
(H50 Max for ESB4-SXI-50) to reach desired torque.
2) Choose [H0F] for unlimited impacts (Shut-off
disabled).
Limit
Limit rotation setup:
1) Limit can be set from [L0F] & [L01]~[L99] rotations
depending on application needs.
2) Choose [L0F] only if you intend to turn off the limit
count on the display.
**Please note: If you press and hold
buttons for each
function it will speed up the selection of desired parameters.