ORIGINAL SAFETY AND OPERATING INSTRUCTIONS 

This manual is for the Delta-Q Technologies RQ Series Industrial Battery Chargers. Read and 
comprehend this document fully before handling or working with any RQ Series battery chargers. 
Important safety, operating, and installation instructions are included. As well, this manual includes a 
link to a list of fault codes and error codes that help engineers take steps quickly to resolve issues.  

Read this information in its entirety before using your Delta-Q Technologies charger. Save these 
instructions.  

For technical support, contact the manufacturer or distributor of your vehicle or machine, as their version 
of this charger may require unique operating instructions. For additional product documentation, see 

www.delta-q.com/resources

. 

Warning 

Use the charger only with an algorithm that is appropriate to the specific battery type and 

capacity of your product. Other usage may cause personal injury and damage. Lead acid batteries may 
generate explosive hydrogen gas during normal charging. Keep sparks, flames, and smoking materials 
away from batteries. If this charger is used with lithium-ion type batteries, an integrated battery 
management system (BMS) must be used. The BMS must ensure that in all operating modes, the battery 
cells are protected from inappropriate levels of voltage, current, temperature, and state of charge. Do not 
operate the charger in a closed-in area or restrict ventilation. Never charge a frozen or non-rechargeable 
battery. Obse

rve all battery manufacturers’ precautions (e.g., maximum charge rates and if cell caps 

should be removed while charging).

 

Danger 

 Risk of electric shock. Connect charger power cord to an AC outlet that has been properly 

installed and grounded in accordance with all local codes and ordinances. A grounded AC outlet is 
required to reduce the risk of electric shock

do not use ground adapters or modify the plug. Do not 

touch uninsulated portions of the output connector or uninsulated battery terminals. Disconnect the AC 
supply before making or breaking the connections to the battery. Do not open or disassemble the 
charger. Do not operate this charger if the AC supply cord or DC output cord is damaged or if the charger 
has received a sharp blow, been dropped, or is damaged in any way. Refer all repair work to the 
manufacturer or qualified personnel. This charger is not intended for use by persons (including children) 
with reduced physical, sensory or mental capabilities, or lack of experience and knowledge on electrical 
systems and battery charging, unless they have been given supervision or instruction concerning use of 
the charger by a person responsible for their safety. Children should be supervised to ensure they do not 
play with the charger

Содержание RQ Series

Страница 1: ... 2021 Delta Q Technologies Corp All Rights Reserved PN 710 0261 Rev 1 Date April 2021 RQ SERIES BATTERY CHARGERS USER MANUAL ...

Страница 2: ...ing Instructions 3 Warning 3 Danger 3 Attention 4 Danger 4 Safe Operating Instructions 5 EMC Declaration 6 Models 7 Mounting Instructions 7 Operating Instructions 7 Charger Interface 8 Charging Algorithms 9 Displaying the Active Algorithm 9 Selecting a Charge Algorithm 9 Fault and Error Codes 10 Identifying the Charger Part Serial Numbers 10 Acronyms 11 ...

Страница 3: ...MS must ensure that in all operating modes the battery cells are protected from inappropriate levels of voltage current temperature and state of charge Do not operate the charger in a closed in area or restrict ventilation Never charge a frozen or non rechargeable battery Observe all battery manufacturers precautions e g maximum charge rates and if cell caps should be removed while charging Danger...

Страница 4: ...ate du chargement Ne jamais charger une batterie gelée ou non rechargeable Prendre connaissance des mesures de précaution spécifiées par le fabricant de la batterie p ex vérifier s il faut enlever les bouchons des cellules lors du chargement et les taux de chargement Danger Risque de décharge électrique Ne pas toucher les parties non isolées du connecteur de sortie ou les bornes non isolées de la ...

Страница 5: ...an cause overheating and can be a fire hazard Ifthe detachable ACinput power cord set or DCoutput cord is damaged do not use the charger until they are replaced with cord sets appropriate to your region andapplication When mated with a Delta Q Technologies sealed AC cord the charger meets IP66 specifications making it dust tight and protectedagainstpowerfulwaterjets Ifacordsetwithanunsealedconnect...

Страница 6: ... particular installation If this equipment does cause harmful interference to radio or television reception which can be determined by turning the equipment off and on the user is encouraged to try to correct the interference by one or more of the following measures Reorient or relocate the receiving antenna Increase the separation between the equipment and receiver Connect the equipment into an o...

Страница 7: ...minum enclosure At each corner are 4 5mm x 8mm diameter slots arranged to allow ample tolerance when mating with standoffs or pre drilled holes in a machine Use M4 screws of an appropriate length to secure the charger to the intended support If mounting the charger on a vehicle or machine frame that may be prone to flexing it is recommended to mount the charger using only three of the mounting poi...

Страница 8: ...d errors Visit the Delta Q Technologies support website at https support delta q com and search for fault and error codes to review recommended actions 4 The Charger button has multiple functions o Short Press less than 4 seconds shows the currently active algorithm o It is also used to select a new algorithm from those loaded on the charger For more information see Selecting a Charge Algorithm So...

Страница 9: ...h battery pack Displaying the Active Algorithm There are up to 25 charge algorithms stored in the charger Use the Charger button to display and or change the active charge algorithm Press and release the Charger button to display the active algorithm It will be displayed twice on the GREEN LED e g Show Active Charge Algorithm 21 Selecting a Charge Algorithm 1 Activating Charge Algorithm Select Mod...

Страница 10: ...ection The GREEN and RED LEDs will be ON for one 1 second and then OFF for one 1 second confirming the algorithm selection e g Confirming Charge Algorithm 13 selection Note You can verify the selected algorithm by displaying the active algorithm FAULT AND ERROR CODES Visit the Delta Q Technologies support website at https support delta q com and search for fault and error codes to review recommend...

Страница 11: ...efinitions used within this guide Term Definition AC Alternating Current AWG American Wire Gauge BMS Battery Management System DC Direct Current EMC Electromagnetic Compliance FCC Federal Communications Commission HV High Voltage LED Light Emitting Diode LV Low Voltage SJTW Hard Service Cord UL Underwriters Laboratories V Volt VAC Volts Alternating Current ...

Страница 12: ...Delta Q Technologies Corp 3755 Willingdon Avenue Burnaby BC V5G 3H3 CANADA Web www delta q com Phone 1 604 327 8244 Delta Q Technologies Corp 3755 Willingdon Avenue Burnaby BC V5G 3H3 CANADA ...

Отзывы: