background image

 

 

GU AR ANTEE 

 

 

TERMS OF GUARANTEE

 

All DELTA OHM instruments are subject to accurate testing, and are guaranteed for 24 months from the 
date of purchase. DELTA OHM will repair or replace free of charge the parts that, within the warranty 
period, shall be deemed non efficient according to its own judgement. Complete replacement is excluded 
and no damage claims are accepted. The DELTA OHM guarantee only covers instrument repair. The 
guarantee is void in case of incidental breakage during transport, negligence, misuse, connection to a 
different voltage than that required for the appliance by the operator. Finally, a product repaired or 
tampered by unauthorized third parties is excluded from the guarantee. The instrument shall be returned 
FREE OF SHIPMENT CHARGES to your dealer. The jurisdiction of Padua applies in any dispute. 

 

The electrical and electronic equipment marked with this symbol cannot be disposed of in public 
landfills. According to the Directive 2011/65/EU, the european users of electrical and electronic 
equipment can return it to the dealer or manufacturer upon purchase of a new one. The illegal 
disposal of electrical and electronic equipment is punished with an administrative fine. 

 

This guarantee must be sent together with the instrument to our service centre. 
IMPORTANT: Guarantee is valid only if coupon has been correctly filled in all details.  

Instrument Code: 

HD50R-MB 

 

 

Serial Number 

 

 

 

RENEWALS 

 

 

Date 

 

Date 

Inspector 

 

Inspector 

Date 

 

Date 

Inspector 

 

Inspector 

Date 

 

Date 

Inspector 

 

Inspector 

 

 

 

  

 

Содержание HD50R-MB

Страница 1: ...in this manual and the instrument you have purchased We cannot completely exclude the possibility of errors in the manual for which we apologize The data images and descriptions included in this manua...

Страница 2: ...D50 2 V1 0 TABLE OF CONTENTS 1 INTRODUCTION 3 2 DESCRIPTION 4 3 CONNECTIONS 5 4 SOFTWARE 8 5 MODBUS 9 6 TECHNICAL CHARACTERISTICS 14 7 INSTRUMENT STORAGE 15 8 SAFETY INSTRUCTIONS 15 9 ORDERING CODES 1...

Страница 3: ...up to 10 TCP IP Client simultaneously If the local network is connected to Internet the data can be regularly sent to an FTP address to the Cloud and via e mail For each detected quantity two alarm th...

Страница 4: ...n gauge 3 Red POWER LED indicates the presence of the external power supply 4 Power supply input 5 RS485 line termination 6 Input for RS485 Modbus RTU sensors 7 RJ45 connector for Ethernet connection...

Страница 5: ...the termination placing the short jumper next to the RS485 connector between the RT and CLOSE indications Otherwise remove the termina tion placing the short jumper between the RT and OPEN indication...

Страница 6: ...ia a standard Ethernet cable The data logger is preset to get a dynamic IP address from the network DHCP server The IP address can be displayed and changed by connecting the data logger to a PC via US...

Страница 7: ...D35AP S software It is possible to restore the factory parameters by placing the short jumper next to the NET RST push button between the 2 and 3 indications and then pressing the NET RST push button...

Страница 8: ...FR21 SOFTWARE OPTION The HD35AP CFR21 option allows in addition to the features of the basic software both HD35AP S and HDServer1 the protection of recorded data and instrument con figuration in respo...

Страница 9: ...units of measurement Index Unit of meas Index Unit of meas Index Unit of meas Index Unit of meas Index Unit of meas 0 C 13 inchHg 26 J m2 39 inch 52 l min 1 F 14 inchH2O 27 J cm2 40 counts 53 gallon...

Страница 10: ...hold alarm 10 SW ABSOLUTE HUMIDITY in g m3 x10 11 B Absolute humidity alarm 0 OFF 1 lower threshold alarm 2 higher threshold alarm 12 SW WET BULB TEMPERATURE in the set measurement unit x10 13 B Wet b...

Страница 11: ...ND SPEED measurement unit see TAB 12 1 5053 SW WIND SPEED resolution 2 100 1 10 0 1 1 0 1 2 0 01 General information 10000 W Year of last measurement 10001 W Month of last measurement 10002 W Day of l...

Страница 12: ...EED ultrasonic anemometer lower alarm threshold in m s x100 93 SW Wind speed ultrasonic anemometer higher alarm threshold in m s x100 94 SW WIND DIRECTION ultrasonic anemometer lower alarm threshold i...

Страница 13: ...59 B User code with ASCII codification of measurement 5 da 20060 a 20071 B User code with ASCII codification of measurement 6 da 20072 a 20083 B User code with ASCII codification of measurement 7 da 2...

Страница 14: ...mples from 259 000 a 890 500 depending on the number of acquired quantities Interfaces ETHERNET RJ45 connector with proprietary TCP IP or Modbus TCP IP protocol USB mini USB connector Master RS485 Mod...

Страница 15: ...the specific measures described in this operating manual The proper operation and the operational safety of the instrument can be ensured on ly under the climatic conditions specified in this manual...

Страница 16: ...Server1 softwares downloadable from Delta OHM web site are included The probes and the CP23 USB cable have to be ordered separately The Ethernet cable is not included Accessories HD35AP CFR21 Software...

Страница 17: ...HD50 17 V1 0 NOTES...

Страница 18: ...HD50 18 V1 0 NOTES...

Страница 19: ......

Страница 20: ...ed third parties is excluded from the guarantee The instrument shall be returned FREE OF SHIPMENT CHARGES to your dealer The jurisdiction of Padua applies in any dispute The electrical and electronic...

Отзывы: