LOCATING THE POWER BURNER
This gas appliance is designed and certified for outdoor use only. Do not locate this Power
Burner under overhead combustible surfaces. Do not operate the Power Burner inside a building,
garage, recreation vehicle or any enclosed area. CAUTION should be taken when grills are used
near glass, vinyl siding or other temperature sensitive construction materials. In some cases it may be
necessary to increase the clearance around the grill to avoid damage to vinyl siding. Check with the
manufacturer of the siding material for details. When choosing an area, consider exposure to wind,
proximity to traffic paths and length of gas supply line. Keep gas supply lines as short as possible to
reduce pressure drop. Keep the Power Burner away from windy area but keep the Power Burner in
a well-ventilated area. Do not obstruct the flow of combustion and ventilation air around the Power
Burner. The supporting edges of the Power Burner must be located level and flat. The counter should
also be leveled.
CLEARANCE TO COMBUSTIBLE CONSTRUCTION
A minimum clearance of 12” from the sides and 12” from the back of the Power Burner
to adja-
cent vertical combustible construction must be maintained.
DÉGAGEMENT DE TOUTE CONSTRUCTION COMBUSTIBLE
Il faut maintenir une distance minimum de
12 po (30.48 cm)
sur les côtés et de
12 po (30.48 cm)
sur
l’arrière du gril par rapport aux constructions combustibles verticales adjacentes.
CLEARANCE TO NONCOMBUSTIBLE CONSTRUCTION
A minimum clearance of 1” from the back of the Power Burner
above cooking surface to
non-combustible construction is required.
A minimum of 1” clearance to the sides of the Power Burner
above cooking surface to non-com-
bustible construction is recommended. The Power Burner can be installed directly next to non-com-
bustible construction below the cooking surface.
DÉGAGEMENT DE TOUTE CONSTRUCTION INCOMBUSTIBLE
Une distance minimum de
1 po (2.54 cm)
de l’arrière du Puissant Bruleur au-dessus de toute surface
de cuisson à la construction incombustible est prescrite. Une distance minimum de
1 po (2.54 cm)
des côtés du Puissant Bruleur au-dessus de la surface de cuisson à la construction incombustible
est recommandée. Le Puissant Bruleur peut être installé directement à proximité d’une construction
incombustible en-dessous de la surface de cuisson.