75
Operation and Installation Manual for SOLIVIA 2.0/2.5/3.0/3.3/3.6/5.0 EU G4 TR
12. Diagnostics and Troubleshooting
EN
12.4 Message Logs
All important events and messages are logged in the solar inverter.
The following logs are created:
●
External events
●
Internal events
●
Log for VDE AR N 4105
●
Change events
●
Autotest for Italy
12.4.1 "External events" log
Menu
781 External events
Description
External events occur outside the solar inverter and affect its oper-
ating behavior.
Accessing the Menu
Main Menu > Production Info > Event Journal > External
Events
➔
USB features
Options
Install settings
Production info
Diagnostic&Alarm
SOLIVIA ##
1. In the main menu, press the
buttons to select
Produc-
tion Info
and then press the
button.
➔
Year statistics
Total statistics
Feed-in settings
Event journal
History
400 Production info
2. Press the
buttons to
select
Event Journal
and then
press the button.
➔
Change events
External events
-------------------
480 Event journal
3. Press the
buttons to se-
lect
External Events
and then
press the button.
➔
Begin 1014V
Voltage too high
16.04.2012 17:25:36
481 External events
4. You can view the whole list by
pressing the
buttons.
Message Structure
Each message consists of three lines defined as follows:
➔
Begin 1014V
Voltage too high
16.04.2012 17:25:36
481 External events
1st Line
Date and time when the external event
occurred.
2nd Line
Short description of the failure (see Chap-
ter
“12.3 Overview of Failure Messages/
Troubleshooting”, p. 73)
3rd Line
Additional information, e.g., "Begin" for the
occurrence of an event or "End" for the
disappearance of an event.
12.4.2 "Internal Events" Log
Menu
620 Internal log
Description
Internal events are problems within the solar inverter. Internal
events should be resolved by Delta Solar Support.
Accessing the Menu
Main menu > Diagnostic&Alarm > Internal Log
➔
USB features
Options
Production info
Diagnostic&Alarm
Inverter info
SOLIVIA ##
1. In the main menu, press
the
buttons to select
Diagnostic&Alarm
and then
press the button.
➔
-------------------
Internal log
-------------------
600 Diagnostic&Alarm
2. Press the
buttons to
select
Internal Log
and then
press the button.
202 222
16.04.2012 17:25:36
620 Internal log
3. You can view the whole list by
pressing the
buttons.
Message Structure
Each message consists of two lines defined as follows:
202 222
16.04.2012 17:25:36
620 Internal log
1st Line
Date and time when the internal event
occurred.
2nd Line
One or more failure numbers