59
Operation and Installation Manual for SOLIVIA 2.0/2.5/3.0/3.3/3.6/5.0 EU G4 TR
10. Settings
EN
Example
The parameters for points A to D are configured in this example as
follows:
Display Text
Description
A cos phi: ind 1.00
Point A: cos φ is set to
inductive
1.00
. Since cos φ = 1.00,
capacitive
could also be configured.
The power ratio P/Pn is automatically
set to 0% and cannot be changed.
B cos phi: ind 0.95
Point B: cos φ is set to
inductive
1.00
.
B P/Pn ratio: 23%
Point B: Power ratio P/Pn is set to
23 %
.
C cos phi: cap 0.90
Point C: cos φ is set to
capacitive
1.00
.
C P/Pn ratio: 75%
Point C: Power ratio P/Pn is set to
75 %
.
D cos phi: cap 0.95
Point D: cos φ is set to
inductive
0.95
.
The power ratio P/Pn is automatically
set to 100 % and cannot be changed.
This results in the following behavior from the solar inverter,
depending on the current fed active power:
Power ratio P/P
n
0 %
50 %
100 %
1
0.8
0.8
Point A
Point B
Point C
Point D
cos φ
inductive
capacitive
Fig. 10.4:
Example of configuring cos φ (P) function
When changing the currently fed active power, the cos φ runs along
the plotted line.
Effects of Active Power Limitation on Behavior of "cos φ (P)"
Function
If active power limitation is configured during commissioning and/or
through the "power reduction" function, the behavior of the "cos φ
(P)" function changes.
Power ratio P/P
n
0 %
50 %
100 %
80 %
1
0.8
0.8
Point A
Point B
Point C
Point D
cos φ
inductive
capacitive
5 kW
4 kW
2.5 kW
Example: SOLIVIA 5.0 EU G4 TR, limited to 4 kW
Fig. 10.5:
Effect of active power limitation on the "cos φ (P)"
function
This active power reduction to 4 kW means point D can never be
achieved. This applies for the entire grey area.
Accessing the Menu
Main Menu > User Settings > Reactive PwCtrl
➔
USB features
Options
Production info
User settings
Diagnostic&Alarm
SOLIVIA ##
1. In the main menu, press the
buttons to select
User
Settings
and then press the
button.
for assistance.
Ask your installer
energy production.
Changes could affect
2. Press the button to confirm.
➔
-------------------
Reactive PwCtrl
Active PwCtrl
-------------------
500
User settings
3. Press the
buttons to se-
lect
Reactive PwCtrl
and then
press the button.
➔
A Cos phi: ind 1.00
Mode: Cos phi(P)
-------------------
520 Reactive PwCtrl
4. Press the
buttons to
select
Mode
and then press
the button.
➔
A Cos phi: ind 1.00
Mode: Cos phi(P)
-------------------
520 Reactive PwCtrl
5. Press the
buttons to set
Mode
to
Cos phi (P)
and then
press the button.
6. Select a parameter with the
buttons. Press the but-
ton to change the value.
Configurable Parameters
(see Fig. 10.3, S. 58)
Display Text
Designation
Description
A cos phi: ind
1.00
Point A: cos φ
inductive 0.8 - 1.0
or
capacitive 0.8 - 1.0
B cos phi: ind
1.00
Point A: cos φ
inductive 0.8 - 1.0
or
capacitive 0.8 - 1.0
B P/Pn ratio:
Point B: Power ratio
P/P
n
1 - 49 %
C cos phi: ind
1.00
Point C: cos φ
inductive 0.8 - 1.0
or
capacitive 0.8 - 1.0
C P/Pn ratio:
Point C: Power
ratio P/P
n
50 - 99 %
D cos phi: ind
1.00
Point D: cos φ
inductive 0.8 - 1.0
or
capacitive 0.8 - 1.0