MASTER SLAVE
SM15K INTERFACES
9 / 19
DELTA ELEKTRONIKA B.V.
rev. Nov. 2019
Switch on the units.
3.5
UNIT CONFIGURATION
The unit will automatically detect the new inserted interface.
The interface icon will be shown in the display, see fig 3 - 4.
Configuring of slaves:
o
To configure a power supply as a slave, via the front menu
go to CONFIGURATION -> MASTER SLAVE -> SETTINGS
and set the state as slave. Press "OK" to confirm.
o
The slave icon will be shown in the display, see fig 3 - 5.
o
The icon will blink as long as the system is in configuration
mode.
o
Once the master is configured, the icon will stop blinking.
Configuring of the master:
o
To configure a power supply as the master, via the front
menu go to CONFIGURATION -> MASTER SLAVE ->
SETTINGS and set the state as master.
o
In the same menu, enter the number of devices that are
connected in series or parallel.
o
Press "OK" to confirm.
o
The master icon will be shown in the display, see fig 3 - 6.
The master or slave can also be configured via the web
interface, or using Ethernet commands.
After changing master or slave settings, stored sequences
need to be rebuilt due to system scaling. See the "Building a
Sequence" paragraph in chapter 7 of the
Sequencer Programming Manual for the SM15K
3.6
TROUBLE SHOOTING
Check there is only one M/S-2 interface installed per unit.
Check that all interfaces are type INT MOD M/S-2, and there
is no INT MOD M/S, see fig 3 - 7.
Check the firmware version as specified in paragraph 3 of this
chapter.
Check the source of the power supply.
Check the web interface for errors in one of the devices.
Use Ethernet or web commands to check for errors in the
master slave system.
3.7
CALIBRATION
Calibration of the interface is not applicable.
fig 3 - 4
Position of the standard interface icon in the unit
display.
fig 3 - 5
Position of the interface Slave icon in the unit
display.
fig 3 - 6
Position of the interface Master icon in the unit
display.
fig 3 - 7
Check for the marking "GEN 2" and " M/S-2"
for the correct interface for SM15K units.