Delta Elektronika SM120-25D Скачать руководство пользователя страница 18

SM3000

OPERATING - TROUBLE SHOOTING - CALIBRATING

rev. February 2018

DELTA ELEKTRONIKA B.V.

Page 4 - 7

7)

OUT PUT VOLT AGE IS HIGHER THAN SET VALUE

Check con nec tions on SENSE BLOCK (on rear panel), For nor -
mal op er a tion there should be a link be tween + and S+ and be -
tween – and S– (see also fig. 4 - 18). When re mote sens ing is
used, check the wires of the sens ing.

8)

OVP LED on.

Check OVP set ting.

Over heating also causes the OVP led to be on, cool ing down will
re set  the  ther mal  pro tec tion.

You are us ing Re mote Sensing.
Even a short volt age pulse >3V be tween – and S – causes the
OVP cir cuit to limit the out put volt age.

Re mote ShutDown volt age is ap plied to the prog. con nec tor.

9)

NO LEDS on.

Over heating can be the cause, cool ing down will re set the ther mal 
pro tec tion.

Check in put power and in put fuses (on rear panel)

Check fuses F400 and F401 on P430, a blown fuse can be
caused by a de fec tive rec ti fier bridge D400 or D401. Note: The
fuses are of a spe cial 500 V type.

The aux il iary power sup ply (board P430) is de fect. Do not try to re -
pair P430 (ex cept for D400, D401, F400 and F401), but send
P430 for re pair or ask for re place ment.

10)

CHECK POINTS IN CASE OF A SE RI OUS FAIL URE

Check out put di odes.
De fec tive di odes give a short.

SM

 

15-200

 

D Check di odes D300 - D315

SM

 

30-100

 

D Check di odes D300 - D309

SM

 

70-45

 

D

Check di odes D300 - D303 on P457

SM

 

120-25

 

D Check di odes D300 - D303 on P458

Re place  de fec tive  parts.

Fuse F200 and / or F201 on P428 are blown.

Prob a bly there is a de fect on one of the two boards P433.
First check out put di odes, see above.

WARNING

: Do not re place F200 or F201until the unit is re paired.

Re placing fuse F200 and F201 while P433 is still de fect will cause
R104 till R109 to blow, this will dam age the board P428.

Note: Do not try to re pair P433, but send the sub unit with 2x P433
for re pair or ask for re place ment.
Pref er a bly con sult fac tory when you dis cover a de fect in P433.

Check fuses on 
rear panel

No Out put

No LED on

Re place  P430,
see 8)

One or mor e
LEDs on

Check fuse F200,
F201 on P428

Pro ceed  with
sec tion:  Fuse
F200, F201 is
blown see 9).

Pro ceed  with
sec tion:  Check
out put  di odes

Blown

O.K.

The unit is not
over heated

fig.  4 - 18

For nor mal op er a tion links should be con nected 

be tween S+ and + and be tween S– and – 

Содержание SM120-25D

Страница 1: ...rlands www DeltaPowerSupplies com Tel 31 111 413656 SM3000 series PRODUCT MANUAL Contents 1 Datasheet 2 Safety Instructions 3 Descriptions 4 Operating Trouble Shooting Calibration 5 EC Declaration of...

Страница 2: ...ution 3 When programming a high voltage unit directly via a PC or via a network connection either ground the negative power output or use a safety isolated interface For more information and schematic...

Страница 3: ...d separately to recycle it responsibly to promote the sustainable reuse of material resources 11 Removal of safety covers Safety cover s are used to cover potentially hazardous voltages Observe the fo...

Страница 4: ...2 INPUT VOLTAGE The power supplies have a wide input volt age range The units need a 3 phase input voltage but no neutral connection is required The units can also operate on one phase but at 90 of t...

Страница 5: ...programming The inputs have a protection circuit formed by a series resistor and a parallel zener see fig 3 7 The capacitor limits the speed to a safe value Note that the analog inputs and outputs ar...

Страница 6: ...gh 13 PROGRAMMING SPEED The response time is measured with a step waveform at the CV prog input Programming from a low to a high output voltage is nearly load independent but programming down to a low...

Страница 7: ...gh energy pulse of about 300 V If there is an electrical connection between the output and the input through the oscilloscope you will get a false reading The suppression for the SM120 25D is lower bu...

Страница 8: ...tch shuts down the output in case of insufficient cooling After cooling down the unit will start working again The thermal protection circuit protects 2 parts separately in the unit the switching tran...

Страница 9: ...recommended for more than 3 units or in combination with Fast Programming option Consult factory for a solution 29 REMOTE SENSING The voltage at the load can be kept constant by remote sensing This fe...

Страница 10: ...ure and full load the fan will run at a very low speed The fan does not operate on no load Normally at 50 C ambient and full load the fan will not work at full speed Since the fan is over rated it wil...

Страница 11: ...ITER circuit so no large inrush cur rent will flow As soon as the voltage is sufficiently high the power supply starts working and the series resistor is bypassed by a relay contact The operating swit...

Страница 12: ...mended to set the OVP on 24 3 27 V Check that the cooling of the unit is not obstructed 2 ANALOG PROGRAMMING Put the appropriate switch es in the position PROGRAM Connect the programming voltage sour...

Страница 13: ...erminals so the OVP setting should be increased by the total voltage drop in the load leads 7 BATTERY CHARGER The CV CC regulated power supplies are ideal battery charg ers Once the output is set at t...

Страница 14: ...ended for more than 4 units consult factory for using more than 4 power supplies in parallel First connect output terminals and test system in normal paral lel operation Ensure that all power connecti...

Страница 15: ...ON For complex combinations as mixed series parallel always use the MASTER SLAVE SERIES ADAPTER product See fig 4 14 for an example of how to connect 2 units in se ries in parallel with 2 units in ser...

Страница 16: ...ly to dry before switching it on again 3 GALVANIC INDUSTRY For using the power supplies in the galvanic industry it is strongly recommended to take precautions against an aggressive environ ment An ag...

Страница 17: ...nt is flowing through pin 1 of the prog connector Please check why current is flowing through pin 1 see also next paragraph 4 and fig 4 17 4 PROGRAMMING OFFSETS Unwanted offsets in the programming can...

Страница 18: ...ry to re pair P430 except for D400 D401 F400 and F401 but send P430 for repair or ask for replacement 10 CHECK POINTS IN CASE OF A SERIOUS FAILURE Check output diodes Defective diodes give a short SM...

Страница 19: ...h exactly 5 00 V Set output voltage to a low value ensuring the power supply is in CC mode Measure the output current with an accurate shunt Cali brate the current with R686 exactly on the rated max c...

Страница 20: ...al EN 55022 Radiated and conducted Class B EN 61000 3 3 Voltage fluctuation and flicker EN 61000 6 1 Generic Immunity residential light industrial EN 61000 6 2 Generic Immunity industrial environment...

Отзывы: