THERMAL CONSIDERATIONS 

 
Thermal management is an important part of the system 
design. To ensure proper, reliable operation, sufficient 
cooling of the power module is needed over the entire 
temperature range of the module. Convection cooling is 
usually the dominant mode of heat transfer. 
 
Hence, the choice of equipment to characterize the 
thermal performance of the power module is a wind 
tunnel. 

 

Thermal Testing Setup 

 
Delta’s DC/DC power modules are characterized in 
heated vertical wind tunnels that simulate the thermal 
environments encountered in most electronics 
equipment. This type of equipment commonly uses 
vertically mounted circuit cards in cabinet racks in which 
the power modules are mounted. 
 
The following figure shows the wind tunnel 
characterization setup. The power module is mounted 
on a test PWB and is vertically positioned within the 
wind tunnel. The space between the neighboring PWB 
and the top of the power module or a heat sink is 
6.35mm (0.25”). 

 

Thermal Derating 

 
Heat can be removed by increasing airflow over the 
module. Figure 18 and 19 show maximum output is a 
function of ambient temperature and airflow rate. To 
enhance system reliability, the power module should 
always be operated below the maximum operating 
temperature. If the temperature exceeds the maximum 
module temperature, reliability of the unit may be 
affected. 

 

Note: Wind Tunnel Test Setup Figure Dimensions are in millimeters and (Inches)

10 (0.4”) 

MODULE 

AIR FLOW 

50.8 (2.0”) 

FACING PWB

PWB 

AIR VELOCITY
AND AMBIENT 

TEMPERATURE 

MEASURED BELOW 

THE MODULE

Figure 17: 

Wind tunnel test setup 

 

 

THERMAL CURVES 

 

Figure 19: 

Output current vs. ambient temperature and air velocity

@V

in

< 60

V

 

 

S48SA1R812(Standard) Output Current vs. Ambient Temperature and Air Velocity

@ Vin < 60V

0

2

4

6

8

10

12

14

65

70

75

80

85

90

95

100

Ambient Temperature (

)

Output Current(A)

Natural

Convection

100LFM

200LFM

300LFM

400LFM

500LFM

600LFM

 

Figure 18:

 Hot spot temperature measured point 

The allowed maximum hot spot temperature is defined at 

110

 

 

 

Содержание 33W Family

Страница 1: ...as extremely high reliability under highly stressful operating conditions All models are protected from abnormal input output voltage and current conditions APPLICATIONS Telecom DataCom Wireless Netw...

Страница 2: ...and Noise 5Hz to 20MHz bandwidth Peak to Peak Full Load 1 F ceramic 10 F tantalum 30 75 mV RMS Full Load 1 F ceramic 10 F tantalum 5 20 mV Operating Output Current Range 0 12 A Output DC Current Limi...

Страница 3: ...Efficiency vs load current for minimum nominal and maximum input voltage at 25 C Figure 2 Power dissipation vs load current for minimum nominal and maximum input voltage at 25 C 0 0 0 1 0 2 0 3 0 4 0...

Страница 4: ...ceramic capacitor Top Trace Vout 50mV div Bottom Trace Iout 5A div Figure 7 Output voltage response to step change in load current 75 50 of Io max di dt 0 1A s Load cap 10 F 100 m ESR tantalum capacit...

Страница 5: ...urement should be made using a BNC cable length shorter than 20 inches Position the load between 51 mm to 76 mm 2 inches to 3 inches from the module 0 0 0 3 0 6 0 9 1 2 1 5 1 8 2 1 0 0 2 0 4 0 6 0 8 0...

Страница 6: ...elta s DC DC power modules are designed to operate in a wide variety of systems and applications For design assistance with EMC compliance and related PWB layout issues please contact Delta s technica...

Страница 7: ...will automatically shut down hiccup mode The modules will try to restart after shutdown If the overload condition still exists the module will shut down again This restart trial will continue until th...

Страница 8: ...n if this feature is not used Figure 15 Circuit configuration for trim down decrease output the external resistor is connected between the TRIM voltage If and Vo pins the output voltage set point decr...

Страница 9: ...n the neighboring PWB and the top of the power module or a heat sink is 6 35mm 0 25 Thermal Derating Heat can be removed by increasing airflow over the module Figure 18 and 19 show maximum output is a...

Страница 10: ...DS_S48SA1R812_06012006 10 PICK AND PLACE LOCATION SURFACE MOUNT TAPE REEL RECOMMENDED PAD LAYOUT SMD...

Страница 11: ...the pin Vout joint 11 LEADED Sn Pb PROCESS RECOMMEND TEMP PROFILE Time sec Pre heat temp 140 180 C 60 120 sec Peak temp 210 230 C 5sec Ramp up temp 0 5 3 0 C sec Temperature C 50 100 150 200 250 300...

Страница 12: ...ut Positive output voltage 2 Vout Negative output voltage 6 Trim Output voltage trim 8 ON OFF ON OFF logic 11 Vin Negative input voltage 12 Vin Positive input voltage Optional Pin Name Function 4 Sens...

Страница 13: ...FA 36V 75V 1 3A 2 5V 10A 88 5 S48SA3R310NRFA 36V 75V 1 3A 3 3V 10A 90 5 S48SA05006NRFA 36V 75V 1 3A 5 0V 6 6A 90 5 S48SA12003NRFB 36V 75V 1 3A 12V 3 0A 90 0 CONTACT www delta com tw dcdc USA Telephone...

Отзывы: