DELTA DORE Pack TYMOOV 10 Скачать руководство пользователя страница 8

EN

14

15

The shutter will not be locked when these stops are subsequently reached.
The motor will reverse its direction slightly so that there is no force on the 
shutter.

3/  Starting up for the fi rst time

> 3s

CR 2430

x 2

x 1

3.2.2 

Setting 1 manual stop + 1 automatic stop

 

Position the shutter

❸ 

Automatic stops

❹ 

The stops are set

Scroll step by step

❷ 

Setting the position of the manual stop

Press  button B on the front panel 
of the remote control, until the LED 

fl ashes green.

Then, press and hold the 

 button for ~3 seconds 

until  the motor is activated 

briefl y

The motor

will be activated 

briefl y

The motor

will be activated 

twice

Press the 

 button until 

the shutter reaches the lower stop.

The stop position

will now automatically 

be set.

> 3s

> 3s

CR 2430

CR 2430

x 1

x 2

3.2.3 

Setting 2 manual stops

 

Position the shutter

 

Setting the position of the first stop (e.g. Upper manual stop)

 

Setting the position of the second stop (e.g. lower manual stop)

❹ 

The stops are now set. Exit the settings mode.

Press the 

 button until the shutter is 

in the required position, then press 

 to 

stop it.

Press the 

 button until the shutter is 

in the required position, then press 

 to 

stop it.

To scroll step by step, briefl y press  then 

release the 

 and 

 buttons at 

the same time.

To scroll step by step, briefl y press  then 

release the 

 and 

 buttons 

at the same time.

Press  button B on the front panel 
of the remote control,until the LED 

fl ashes green.

Then, press and hold
the 

 button for ~3 

seconds until  the motor is 

activated  briefl y. The upper 

manual  stop will now be set.

The motor

will be activated briefl y.

Press the 

 button 

to  move the shutter to the 
required position,  then 
press 

 to stop it.

Press  button B on the front panel 
of the remote control, until the LED 

fl ashes green.

Then press the 

 button 

for ~ 3 seconds until the motor is 

activated briefl y.

 The lower manual stop will now 
be set.

When the  setting of 

the 2nd stop is completed, 

the motor will validate by 

 activating itself twice.

Scroll step by step

Содержание Pack TYMOOV 10

Страница 1: ...EN Wireless Tubular Motor range TYMOOV radio xRP DxRP xRE...

Страница 2: ...ed in a visible area Frequently check the equipment to detect any imbalances or signs of wear or damage to cables and springs Do not use the device when repairs or adjustments are required Preliminary...

Страница 3: ...rmal shutdown the motor will operate again after a time period of approximately 30 seconds To operate again for 4 minutes the motor must have returned to room temperature If an attempt is made to rais...

Страница 4: ...on with an alarm control unit 21 12 1 Associating the motor intruder mode with the alarm control unit 21 12 2 Defining the motor s operating mode 22 13 Your remote control is lost or not functioning 2...

Страница 5: ...ogue Model Length for drilling L Total length TYMOOV 10 Nm and 20 Nm 395 mm 422 mm Tube L length for drilling wheel attachment by screws or rivet 1 3 Motor head position The motor head must be positio...

Страница 6: ...e The corresponding shutter will be activated brie y once Once the motor has been found press briefly After a few seconds the shutter will be activated briefly twice to confirm the association To exit...

Страница 7: ...slightly so that there is no force on the shutter x 1 Upper physical stop Lower physical stop Stop on shutter blade Press the button briefly until the shutter reaches the upper stop The stop position...

Страница 8: ...the position of the second stop e g lower manual stop The stops are now set Exit the settings mode Press the button until the shutter is in the required position then press to stop it Press the butto...

Страница 9: ...tter to be associated e g new remote control On the new remote control press the and buttons at the same time for more than 3 seconds until the LED comes on The motor will briefly be activated twice Y...

Страница 10: ...will be activated briefly Once high sensitivity Twice low sensitivity Repeat the operations above to switch between modes Press button B on the front panel of the remote control twice until the LED fl...

Страница 11: ...e alarm control unit Define the motor s operating mode Intruder surveillance will only be active if the alarm is activated and the shutter closed 12 1 Associating the motor intruder mode with the alar...

Страница 12: ...cted to the same circuit breaker and are not concerned by the change of remote control After reactivating operate each of them once using their master remote control before associating the new remote...

Страница 13: ...is a fault linked to the end of travel settings and reset them The green LED does not flash after briefly pressing button B Several motors are associated with the remote control Therefore you cannot...

Страница 14: ...www deltadore com 10 19...

Отзывы: