Recommendations

- Cables going through a metal wall must be protected and isolated by 

a sleeve. 
The TYMOOV xRP/DxRP or xRE cable can be disassembled.

- If the power cable is damaged, it must be replaced by the 

manufacturer, after-sales service or similarly qualified personnel in 

order to prevent hazards.

- The motor must be chosen according to the requirements of the load 

bearing support. See our charts for selecting the motor according to 
the shutter type. A plate on the motor indicates the nominal torque 
and operating time.

- TYMOOV xRP/DxRP or xRE tubular motors are designed to 

operate intermittently (4 minutes of continuous operation). They 
are electronically protected to prevent overheating. If there is a 
thermal shutdown, the motor will operate again after a time period 
of approximately 30 seconds. To operate again for 4 minutes, the  
motor must have returned to room temperature.

- If an attempt is made to raise the shutter (for example: intruder test), 

the motor will lower the apron. Caution, your fingers may be caught.

DELTA DORE hereby declares that the motorised systems covered by these 

instructions comply with the essential requirements set out by the Machinery 

Directive 2006/42/EC and the European directive RED 2014/53/EU.

The EU declaration for this equipment is available on request

 

from:

Service “Info techniques”

DELTA DORE – 35270 Bonnemain (France)

email: [email protected]

DELTA DORE

35270 - BONNEMAIN - France

[email protected]

Because of changes in standards and equipment, the characteristics given in the text and the illustrations in this 

document are not binding unless confirmed by our departments.

Содержание Pack TYMOOV 10

Страница 1: ...EN Wireless Tubular Motor range TYMOOV radio xRP DxRP xRE...

Страница 2: ...ed in a visible area Frequently check the equipment to detect any imbalances or signs of wear or damage to cables and springs Do not use the device when repairs or adjustments are required Preliminary...

Страница 3: ...rmal shutdown the motor will operate again after a time period of approximately 30 seconds To operate again for 4 minutes the motor must have returned to room temperature If an attempt is made to rais...

Страница 4: ...on with an alarm control unit 21 12 1 Associating the motor intruder mode with the alarm control unit 21 12 2 Defining the motor s operating mode 22 13 Your remote control is lost or not functioning 2...

Страница 5: ...ogue Model Length for drilling L Total length TYMOOV 10 Nm and 20 Nm 395 mm 422 mm Tube L length for drilling wheel attachment by screws or rivet 1 3 Motor head position The motor head must be positio...

Страница 6: ...e The corresponding shutter will be activated brie y once Once the motor has been found press briefly After a few seconds the shutter will be activated briefly twice to confirm the association To exit...

Страница 7: ...slightly so that there is no force on the shutter x 1 Upper physical stop Lower physical stop Stop on shutter blade Press the button briefly until the shutter reaches the upper stop The stop position...

Страница 8: ...the position of the second stop e g lower manual stop The stops are now set Exit the settings mode Press the button until the shutter is in the required position then press to stop it Press the butto...

Страница 9: ...tter to be associated e g new remote control On the new remote control press the and buttons at the same time for more than 3 seconds until the LED comes on The motor will briefly be activated twice Y...

Страница 10: ...will be activated briefly Once high sensitivity Twice low sensitivity Repeat the operations above to switch between modes Press button B on the front panel of the remote control twice until the LED fl...

Страница 11: ...e alarm control unit Define the motor s operating mode Intruder surveillance will only be active if the alarm is activated and the shutter closed 12 1 Associating the motor intruder mode with the alar...

Страница 12: ...cted to the same circuit breaker and are not concerned by the change of remote control After reactivating operate each of them once using their master remote control before associating the new remote...

Страница 13: ...is a fault linked to the end of travel settings and reset them The green LED does not flash after briefly pressing button B Several motors are associated with the remote control Therefore you cannot...

Страница 14: ...www deltadore com 10 19...

Отзывы: