GENERAL SAFETY INFORMATION

READ AND SAVE THESE INSTRUCTIONS 

GENERAL SAFETY INFORMATION

1.  Make sure that the electric service supply voltage is AC 

120V, 60Hz.

2.  Follow all local electrical and safety codes, as well as 

the National Electrical Code (NEC) and the Occupational 
Safety and Health Act (OSH Act).

3.  Always disconnect the power source before working on 

or near the ventilating fan, motor or junction box.

4.  Protect the power cord from sharp edges, oil, grease, 

hot surfaces, chemicals or other objects.

5.  Do not kink the power cord.
6.  Do not install the unit where ducts are confugured as 

shown in Fig.A.

7.  Provide suction parts with proper ventilation.
8.  This unit is UL Listed for use over a bathtub or shower 

when installed in a GFCI protected branch circuit.

WARNING

TO REDUCE THE RISK OF FIRE, ELECTRIC 
SHOCK, OR INJURY TO PERSONS, OBSERVE THE 
FOLLOWING:

1.  Use this unit only in the manner intended by the 

manufacturer. If you have questions, contact the 
manufacturer.

2. 

Before servicing or cleaning the unit, switch the power off 

at the service panel and lock the service disconnecting 
means to prevent the power from being switched on 
accidentally. When the service disconnecting means 
cannot be locked, securely fasten a prominent warning 
device, such as a tag, to the service panel.

3.  Installation work and electrical wiring must be done by 

a qualified person(s) in accordance with all applicable 
codes and standards, including fire-rated construction.

4. 

Sufficient air is needed for proper combustion and 
exhausting of gases through the flue (chimney) of fuel 

burning equipment to prevent backdrafting. Follow the 
heating equipment manufacturer’s guideline and safety 
standards such as those published by the National 
Fire Protection Association (NFPA), and the American 
Society for Heating Refrigeration and Air Conditioning 
Engineers (ASHRAE) and local code authorities.

5.  When cutting or drilling into the wall or ceiling, do not 

damage electrical wiring and other hidden utilities.

6.  Ducted ventilating fans must always be vented to the 

outdoors.

7.  If this unit is to be installed over a tub or shower, it 

must be marked as appropriate for the application 
and be connected to a GFCI (Ground Fault Circuit 
lnterrupter) – protected branch circuit.

8.  Do not use this unit with any other solid-state control 

device. Solid-state controls may cause harmonic 
distortion, which can cause a motor humming noise.

9.  NEVER place a switch where it can be reached from a 

tub or shower.

10.  Not to be installed in a ceiling thermally insulated to a 

value greater than R40. (This is required for installation 
in Canada only).

 

Turning angle too large

Too many elbows

Fig. A

Duct shrink

Elbow near the body

.

Body

Minimum 18 in.

CAUTION

1.  For general ventilating use only. Do not use to exhaust 

hazardous or explosive materials and vapors.

2.  Not for use in cooking areas. (Fig.B)
3.  This product must properly connect to the grounding 

conductor of the supply circuit.

4.  To reduce the risk of injury to persons, install the fan at 

least 8.2 feet (2.5m) above the floor.

Cooking area

Do not install above or

inside this area

Cooking

Equipment

Fig. B

floor

45

°

45

°

Содержание SIG80-110ELED

Страница 1: ...tructions Existing Construction Assembly Instructions Care and Maintenance Operation Troubleshooting Dimensions Product Specifications Warranty 2 3 4 4 5 7 12 12 13 14 14 15 READ AND SAVE THESE INSTRUCTIONS Address 46101 Fremont Boulevard Fremont CA 94538 US Toll Free Number 1 888 979 9889 Technical Support 1 877 685 4384 Customer Sales Support www deltabreez com ...

Страница 2: ...BB C B D PART DESCRIPTION QTY A Fan housing 1 B LED light panel 1 C Duct adapter optional 1 D Suspension bracket 4 HARDWARE CONTENTS Images are to scale 8 Long Wood Screw ø 4 x 25mm 4 Short Machine Screw 8 32x1 4 6 in to 4 in ...

Страница 3: ...icient air is needed for proper combustion and exhausting of gases through the flue chimney of fuel burning equipment to prevent backdrafting Follow the heating equipment manufacturer s guideline and safety standards such as those published by the National Fire Protection Association NFPA and the American Society for Heating Refrigeration and Air Conditioning Engineers ASHRAE and local code author...

Страница 4: ...hardware store DIMENSION REQUIREMENTS Ceiling Opening L Ceiling Opening W Ceiling Opening H 10 1 4 in 10 1 4 in 7 7 8 in Proper insulation around the fan to minimize building heat loss and gain 6 circular duct is recommended for installation The ducting from this fan to the outside of building has a strong effect on the air flow noise and energy use of the fan Use the shortest straightest duct rou...

Страница 5: ... using the short machine screws BB Note The bottom of the fan housing A should be flush with the bottom of the ceiling board 2 1 Hardware Used AA Long wood screw 8 BB Short machine screw 4 3 Remove the fan junction box cover 3 1 Using wire nuts not supplied connect the house wires 3 2 to the fan wires 3 3 as shown in the wiring diagram on page 4 14 AWG is the smallest conductor that can be used fo...

Страница 6: ...ot included to secure the ducting to the adapter to create an air tight seal 5 Insert the LED connector 5 1 on the LED light panel B into the fan housing A 6 Attach LED light panel B by pinching the mounting springs 6 1 and inserting them into the narrow rectangular slots 6 2 on both sides of the fan housing A Using the switch on the back of grille choose the color temperature you want for your LE...

Страница 7: ... for the fan housing A NOTE One edge of the 10 1 4 in x 10 1 4 in cut out must be a long the joist for proper installation If not possible then attic access and brackets will need to be used see step 2 on page 10 2 Remove fan motor 2 1 from fan housing A by removing the screws where shown 2 2 Gently pull the motor out from the fan housing 3 Remove duct connector 3 1 by removing the duct connector ...

Страница 8: ...g A should be flush with the bottom of the ceiling board 5 2 Hardware Used AA Long wood screw 3 6 To attach the duct connector 6 1 pull the existing ducting 6 2 into the fan housing A Connect the duct connector to the ducting using duct tape not included or clamp not included to create an air tight seal Push ducting 6 2 back through the fan housing A and secure the duct connector 6 1 by sliding it...

Страница 9: ...l B into the fan housing A 9 Attach LED light panel B by pinching the mounting springs 9 1 and inserting them into the narrow rectangular slots 9 2 on both sides of the fan housing A Using the switch on the back of grille choose the color temperature you want for your LED You can choose from 2700K warm white 4000K cool white and 5000K daylight white 7 1 A 8 1 B A 9 1 9 2 9 1 B A 7 8 9 CCT Switch ...

Страница 10: ... the fan housing A 2 ATTACHING TO THE JOIST For joist spacing 16 in 24 in insert two suspension brackets D into the bracket covers on each side of the fan housing A as shown 2 1 and 2 2 3 Secure the suspension brackets D to the joists with long wood screws AA and secure the suspension brackets D to the fan housing A using the short machine screws BB Note The bottom of the fan housing A should be f...

Страница 11: ...on box cover 4 1 5 Connect a 6 in circular duct 5 1 not supplied and vent to the outside Secure it with duct tap not included or clamp not included to make the connection secure and air tight Note If available ducting is 4 inches in diameter the optional duct adapter C can be used to reduce the 6 in duct connector 5 2 on the fan housing A to the 4 in ducting Use duct tape not included or clamp not...

Страница 12: ...FETY INFORMATION before proceeding Routine maintenance should be done at least once a year Wipe down LED light panel with a damp cloth Remove excess dirt and dust from the fan housing with a vacuum cleaner Do not use solvents thinner or harsh chemicals for cleaning the fan Do not allow water to enter the motor Do not immerse LED light panel into water Single speed control mode Turn the POWER switc...

Страница 13: ...y If the damper has become damaged please call Customer Service 3 Be sure you do not have any sharp bends in duct closer than 18 in to the fan discharge 4 Use recommended size ducting to reduce fan noise 5 Be sure the fan is securely attached to your ceiling joists The fan is not clearing the room 1 Insufficient intake airfow within room 2 Insufficient CFM 1 Be sure a door or window is slightly aj...

Страница 14: ... 94 4 Unit Inches mm PRODUCT SPECIFICATIONS Model No Voltage V Frequency Hz Air Flow 0 1 SP CFM Power 0 1 SP W Max Current Amps Weight lb Light Spec SIG80 110ELED 120 60 110 36 0 48 10 1 13W LED 1000 Lumens 2700K 4000K 5000K Note Design and specifications subject to change without notice ...

Страница 15: ...cidental consequential punitive or special damages arising out of or in connection with products use or performance regardless of the form of action whether in contract tort including negligence strict product liability or otherwise 4 This warranty does not extend to fluorescent lamp starters and tubes 5 The warranty does not cover if user does not comply with manufacturer s installation manual 6 ...

Отзывы: