Trigno Quattro, Duo, Mini EMG Sensor User’s Guide 

13 

“Mini” Analog Output Configuration 

 

 

Sampling Rate 

Data Type 

Bandwidth 

Ch. x.1 

1926 sa/sec 

EMG 

20-450 Hz 

Ch. x.2 

148 sa/sec 

ACC or Gyro X 

DC-50 Hz 

Ch. x.3 

148 sa/sec 

ACC or Gyro Y 

DC-50 Hz 

Ch. x.4 

148 sa/sec 

ACC or Gyro Z 

DC-50 Hz 

Table 4: “Mini” Analog Output signal details. Note that sampling rates are approximate; 

please refer to specification table for precise sampling periods. 

 

Figure 3: “Mini” Analog Output Data Flowchart 

 

**Refer to the Trigno System User Guide for more information on Analog Output 

Operation.** 

Placing the Trigno Sensor on the Skin 

Trigno Quattro, Duo and Mini Sensors consist of a main sensor body and four, 

two or one cabled detection head(s) respectively.  The sensor heads should be 

placed near the centroid of the muscle to detect the maximum amount of EMG 

activity.    The sensor body should be affixed in a convenient nearby location to 

provide a detection reference point.    The sensor body and sensor head are 

easily attached to the skin using the Delsys Adhesive Sensor Interfaces.    The 

sensor arrow on the top side should be oriented parallel to the direction of the 

muscle fibers. 

 

 

Figure 6. The EMG sensor head must be positioned overtop of the muscle of interest. The 

reference contacts can be positioned in a convenient nearby location. 

EMG contacts 

reference contacts 

Содержание Trigno Duo EMG

Страница 1: ...ght 2019 by Delsys Incorporated MAN 039 1 1 MP1193B August 2019 No part of this document may be reproduced transmitted transcribed stored in a retrieval system or translated into any language in any f...

Страница 2: ...attro Duo Mini Sensors 11 Using the Analog Outputs if Equipped 11 Quattro Analog Output Configuration 11 Duo Analog Output Configuration 12 Mini Analog Output Configuration 13 Placing the Trigno Senso...

Страница 3: ...muscle reeducation Interpretation of the EMG and supporting signals by a qualified individual is required Rx ONLY Contraindications DO NOT USE on Patients with implanted electronic devices of any kind...

Страница 4: ...iscomfort occurs Immediately discontinue device use if a change in the device s performance is noted Contact Delsys technical support for assistance Delsys Inc guarantees the safety reliability and pe...

Страница 5: ...27 Trigno Duo Sensor Model SP W06 024 Trigno Mini System Model DS T03 FCCID W4P SP W06 Sensor FCCID W4P SP W02 Base Station IC 8138A DST03 System 211 190332 DS T03 211 190333 SP W06 This device compli...

Страница 6: ...at interference will not occur in a particular installation If this equipment does cause harmful interference to radio or television reception which can be determined by turning the equipment off and...

Страница 7: ...neration triggering scenarios and digital integration through the Trigno SDK Software Development Kit and the Trigno API Application Program Interface Refer to the Trigno System User Guide for System...

Страница 8: ...es using the Bluetooth Low Energy BLE industry standard protocol Note that the information bandwidth when operating over Bluetooth is limited by the Bluetooth protocol and the host device capabilities...

Страница 9: ...oves sensor durability and performance Common household magnets can be used to perform these functions as well Sensor LED Feedback States Trigno Avanti sensors indicate their status through various LE...

Страница 10: ...check on power up 8 Scan Base Sensor was previously paired and is scanning for the active base station 9 Low Power Scan Base Sensor was previously paired and has been scanning for the active base stat...

Страница 11: ...th and sampling rate are configured by the software 3Note that the magnetometer has a fixed range and a fixed bandwidth 4An onboard RMS calculation can be invoked to reduce data transmission rates and...

Страница 12: ...Ch 3 1 7 1 1926 sa sec EMG 20 450 Hz 4 Ch 4 1 8 1 1926 sa sec EMG 20 450 Hz 5 Ch 9 1 13 1 1926 sa sec EMG 20 450 Hz 6 Ch 10 1 14 1 1926 sa sec EMG 20 450 Hz 7 Ch 11 1 15 1 1926 sa sec EMG 20 450 Hz 8...

Страница 13: ...e Trigno Sensor on the Skin Trigno Quattro Duo and Mini Sensors consist of a main sensor body and four two or one cabled detection head s respectively The sensor heads should be placed near the centro...

Страница 14: ...ally designed adhesive interfaces to simplify sensor attachment These hypo allergenic interfaces are manufactured from medical grade adhesive approved for dermatological applications Usage of the inte...

Страница 15: ...operation While the sensors are sealed and are water resistant these should never be completely submerged in any liquid The sensor contacts are made of pure silver and are quite soft Care should be ta...

Страница 16: ...2 Sensor skin contacts are made from pure silver and should not be used if allergic reactions to silver are expected or found to occur Electrical Specifications RF Frequency Band 2400 2483 MHz ISM ban...

Страница 17: ...Bandwidth 8 Hz Gyro Range 7 dps Gyro Resolution 7 bits 1 2 4 0 9 1111 20 450 11 22 16 2 4 4 0 45 2222 20 450 10 850 11 22 16 1 The Trigno System is designed with 16 data slots for wireless transmissio...

Страница 18: ...111 20 450 11 22 16 1 35 741246 2 4 8 16 16 1 35741361 250 500 1000 2000 16 1 The Trigno System is designed with 16 data slots for wireless transmission Sensors can occupy up to 4 slots depending on t...

Страница 19: ...2 16 13 5 74 28 11 4 4 0 5 2000 20 450 10 850 11 22 16 13 5 74 32 1 The Trigno System is designed with 16 data slots for wireless transmission Sensors can occupy up to 4 slots depending on the samplin...

Страница 20: ...can occupy up to 4 slots depending on the sampling rate settings 2 Sampling period is the precise time elapse between samples in milliseconds The sampling rate is a rounded expression of 1 sampling p...

Страница 21: ...16 data slots for wireless transmission Sensors can occupy up to 4 slots depending on the sampling rate settings 2 Sampling period is the precise time elapse between samples in milliseconds The sampl...

Страница 22: ...precise time elapse between samples in milliseconds The sampling rate is a rounded expression of 1 sampling period expressed as samples second sa sec 3 RMS window is the period of raw signal that is...

Страница 23: ...Hz Gyro Range 10 dps Gyro Resolution 7 bits 1 1 0 465 2148 20 450 10 850 11 22 16 2 2 0 23 4370 20 450 10 850 11 22 16 1 The Trigno System is designed with 16 data slots for wireless transmission Sen...

Страница 24: ...000 16 9 2 135 17 1259 20 450 11 22 16 3 375 296 111 2 4 8 16 16 1 35 741 361 250 500 1000 2000 16 10 2 25 4000 20 450 10 850 11 22 16 13 5 74 24 2 4 8 16 16 13 5 74 24 250 500 1000 2000 16 11 1 2 7 3...

Страница 25: ...uattro Duo Mini EMG Sensor User s Guide 25 Denotes onboard RMS calculation of the EMG signal Denotes onboard 3 DOF accelerometer data Denotes onboard 3 DOF gyroscope data Denotes analog output support...

Страница 26: ...esigned with 16 data slots for wireless transmission Sensors can occupy up to 4 slots depending on the sampling rate settings 2 Sampling period is the precise time elapse between samples in millisecon...

Отзывы: