![DelRay MONTIGO DRL3613LI Скачать руководство пользователя страница 31](http://html1.mh-extra.com/html/delray/montigo-drl3613li/montigo-drl3613li_installation-and-maintenance-manual_2471113031.webp)
31
Installation
XG0226 - 042220
Cut standard Gyproc / Drywall board to complete the installation of
the surround. Fit the edge of the board to the rim around the fireplace
opening. Fasten the board in place using standard drywall screws.
SINGLE SIDED
Top (Qty 1)
Sides (Qty 2)
Figure 28.
Supplied non-combustible cement board dimensions
Cement Board Install
Install the supplied non-combustible cement board to overlap
the new horizontal & vertical 2 x 4's, place the non-combustible
wall board above the fireplace throat, allowing 1/8" clearance
from the rim above the fireplace opening. Pre-drill the board with
1/8" drill bit and secure to framing with nails, use flat head sheet
metal screws to fasten the board to the metal header.
977
38 7
16 "
305
12"
101
4"
728
28 11
16 "
101
4"
1
2
2
REVISIONS
REV.
DESCRIPTION
DATE
CHANGED BY
B
CHANGED COMPONENTS.
12/10/2018
DM
ITEM NO. PART NUMBER
DESCRIPTION
MATERIAL
QTY.
1
CBMNR36T
Top Cement
Board
1/2" Firepro
Wallboard
1
2
CBMNR36S
Side Cement
Board
1/2" Firepro
Wallboard
2
1:8
DWG. NO.
SHEET 1 OF 1
WEIGHT:
MNR36 Cement Board Assembly
Finish
MATERIAL
DIMENSIONS ARE IN INCHES
TOLERANCES:
FRACTIONAL 1/32"
TWO PLACE DECIMAL .015"
THREE PLACE DECIMAL .005"
ANGULAR .5
ALL BENDS ARE ASSUMED
TO BE 90 UNLESS NOTED
OTHERWISE.
Revision / Date
Drawn by
DATE
NAME
28/08/2018
THE INFORMATION CONTAINED IN THIS DRAWING IS THE SOLE PROPERTY OF CANADIAN HEATING PRODUCTS. ANY REPRODUCTION IN PART OR AS A WHOLE WITHOUT THE WRITTEN PERMISSION OF CANADIAN HEATING PRODUCTS IS PROHIBITED.
PROPRIETARY AND CONFIDENTIAL
Y:\Products\Residential Products\R&D Projects\DelRay\DelRay Lin
ear\MNR36\CAD Drawings\MNR36 Cement Board Assembly
December-18-19 2:05:24 PM
SCALE
DM
Description
MNR36 Cement Board Assembly
B
Revision
DRL3613 DIMENSIONS
A
B
C
387/16
12
2811/16
DRL4813 DIMENSIONS
A
B
C
507/16
12
2811/16
DRL6013 DIMENSIONS
A
B
C
627/16
16
3211/16
A
B
C
Figure 19.c
Sidewall clearances
Edge of door frame
Sidewall
TOP OF UNIT
Sidewall clearances
Side wall clearances are 4". Combustible surrounds may be installed
with 4" clearance to the side of the fireplace as shown.
4" clearance in sidewall drawing does not apply to recession, unit
cannot be recessed into a wall.
Cement board is not needed when the chase is vented, drywall can be
used to finish up to the fireplace opening.
NOTICE
NOTICE
4"
Min.
Содержание MONTIGO DRL3613LI
Страница 53: ...53 Notes XG0226 042220...