![DelRay MONTIGO DRL3613LI Скачать руководство пользователя страница 14](http://html1.mh-extra.com/html/delray/montigo-drl3613li/montigo-drl3613li_installation-and-maintenance-manual_2471113014.webp)
14
Installation
XG0226 - 042220
Co-linear venting into existing masonry chimney
Figure 99.a
Co-linear top vented configuration.
Hearth
10'
Min.
30'
Max.
Dual 3"
liners
• Maximum 30 feet vertical pipe
• Minimum 10 feet vertical
• Restrictor usage recommended for longer vertical runs
•
Keep the flexible liner as straight as possible, avoid unnecessary
bending
•
A maximum of two certified couplers may be used per length of 3" liner
•
DelRay co-linear installation requires reducing from Montigo 4/7
to Duravent 4x6⅝
The appliance can be adapted to co-linear applications using an existing
chimney. The appliance must not be connected to a chimney flue serving
a separate solidfuel burning appliance such as a wood burning fireplace.
The unit must be fully enclosed while maintaining clearances to
combustibles detailed elsewhere in this manual
NOTICE
46DVA-AD-M1
(Part converts Montigo 4/7 to Duravent 4/6⅝)
46DVA-CLAA
(Converts Duravent Direct vent to Co-Linear)
46DVA-CL33K
(High wind termination)
Co-linear
portion of
vent system
may only be
installed within
the fireplace
cavity and
chimney.
Содержание MONTIGO DRL3613LI
Страница 53: ...53 Notes XG0226 042220...