Figure 3.2 Levelling Feet
3.2 Electrical connections
The electrical supply
MUST
have a grounded (Earth) connection.
The cable connected to the YDT-35 MUST carry a grounded (Earth) conductor.
1. Make the electrical connection but do not switch the power on (refer to Figure 3.3).
Figure 3.3 Mains Electrical Connection
3.3 Air Services connection
NOTE:
Ensure the air supply connected to the YDT-35 meets the required technical specification.
Clean, dry air
Minimum pressure 5 bar (72.5 psi)
Maximum 10 bar (145 psi)
Minimum flow rate 100L/min.
Hose Dimensions: 8mm inlet hose diameter.
100-250Vac
50/60Hz
THIS IS AN UNCONTROLLED DOCUMENT downloaded by Lukas Matuska on 16 Feb 2016
Any technical intervention requires certified Hartridge training. Contact Hartridge Ltd for details.