![Delphi Multec 3.5 Скачать руководство пользователя страница 163](http://html1.mh-extra.com/html/delphi/multec-3-5/multec-3-5_applications-manual_2471047163.webp)
Multec 3.5 Fuel Injector Application Manual
Appendix
Delphi Energy and Chassis Systems
Revision: 11/05-1 10-9
CHARACTERISTIC
APPLICATION
MANUAL
SECTION(S)
CAPABILITY/
RECOMMENDATION
VERIFICATION
RESULT
4.4.1
Acceptable to application
Voltage
3.15
3.6
5.3.6
8.4.9
9.3.6
Defined limits acceptable to
application
Dust
3.16.2
Acceptable to application
Humidity
3.16.2
Acceptable to application
Fuel Pressure
3.16.2
5.2.3.2
Vacuum biasing utilized
5.3.6
7.3.6
Table 8-1
9.3.5
Acceptable to application
Icing
2.2.7.4
8.4.12
Application robust to icing
Calibration:
8.3
DVT tests simulate calibration
limits
8.4.7
Calibration robust to DI fuels
8.4.8
Application pass spark plug
fouling tests
Slope
5.2.2.1
Slope acceptable to application
Offset
5.2.2.2
Voltage offsets acceptable to
application
Voltage Flow Curve
5.2.2.4
5.3.6
8.4.9
Acceptable to application
Low Pulse Width
Correction
5.2.2.3
8.4.6
LPW correction table
acceptable to application
Fuel Pump Correction
Содержание Multec 3.5
Страница 2: ......
Страница 120: ......
Страница 140: ......
Страница 154: ......
Страница 170: ...Appendix Multec 3 5 Fuel Injector Application Manual 10 16 Delphi Energy and Chassis Systems Revision 11 05 1...