Delphi 9330-150-A01 Скачать руководство пользователя страница 2

Model 9330-150-A01 Installation Instructions 

 

Page 2 of 16 

Document: INS-9330-A01, Rev. C 

Do not copy or distribute without written permission. Unpublished Work 

 2022 Delphi Display Systems, Inc. All rights reserved. 

Printed copies are Uncontrolled unless clearly marked as a Controlled document. User is responsible for verifying document is the current revision. 

 

 

Table of Contents 

1

 

INTRODUCTION .......................................................................................................................................... 4

 

2

 

WARNINGS .................................................................................................................................................. 4

 

3

 

ENDURA

®

 15X MODEL 9330-150-A01 SPECIFICATIONS ............................................................................ 5

 

4

 

SYSTEM OVERVIEW ..................................................................................................................................... 6

 

4.1

 

F

RONT OF 

D

ISPLAY

 ................................................................................................................................................. 6

 

4.2

 

B

ACK OF 

D

ISPLAY

 ................................................................................................................................................... 6

 

5

 

SYSTEM CONNECTIONS ............................................................................................................................. 7

 

5.1

 

D

IRECT 

N

ETWORK 

C

ONNECTION TO 

POS ................................................................................................................ 7

 

5.2

 

S

ERIAL 

S

ERVER 

C

ONNECTION TO 

POS ..................................................................................................................... 8

 

5.3

 

S

ERIAL 

S

ERVER 

C

ONNECTIVITY

 ................................................................................................................................. 8

 

5.4

 

V

IDEO 

E

NCODER 

C

ONNECTION TO 

POS

 

V

IDEO 

O

UTPUT

 ........................................................................................... 9

 

5.5

 

S

UPPLIED 

E

QUIPMENT

 .......................................................................................................................................... 10

 

5.6

 

D

ISPLAY 

M

OUNTING 

O

PTIONS

 .............................................................................................................................. 10

 

6

 

INSTALLATION PROCEDURES .................................................................................................................. 10

 

6.1

 

CAT5

 

C

ABLE 

T

ERMINATION AT THE 

D

ISPLAY

 .......................................................................................................... 10

 

6.2

 

C

ONNECTING 

P

OWER AND 

D

ATA TO THE 

D

ISPLAY

 ................................................................................................... 13

 

7

 

SYSTEM TEST ............................................................................................................................................. 14

 

8

 

TROUBLE SHOOTING ............................................................................................................................... 14

 

8.1

 

V

ERIFY 

E

THERNET 

C

ABLE IS 

T

ERMINATED 

C

ORRECTLY

 .............................................................................................. 14

 

8.2

 

V

ERIFY 

N

ETWORK 

S

WITCH 

C

ONFIGURATION

 ........................................................................................................... 14

 

8.3

 

V

ERIFY 

P

OINT OF 

S

ALE IS 

C

ONFIGURED 

C

ORRECTLY

 ................................................................................................ 14

 

8.4

 

V

ERIFY 

S

ERIAL 

S

ERVER IS 

C

ONFIGURED 

C

ORRECTLY

 ................................................................................................. 14

 

8.5

 

V

ERIFY 

V

IDEO 

E

NCODER IS 

C

ONFIGURED 

C

ORRECTLY

 .............................................................................................. 14

 

8.6

 

V

ERIFY 

D

ISPLAY 

C

ONNECTIVITY WITH 

POS

 

E

MULATOR

 ............................................................................................ 14

 

9

 

TECHNICAL SUPPORT ............................................................................................................................... 15

 

10

 

DISPLAY DIMENSIONS ............................................................................................................................. 15

 

11

 

DOCUMENT REVISIONS ........................................................................................................................... 16

 

 

 

 

Содержание 9330-150-A01

Страница 1: ...itten permission Unpublished Work 2022 Delphi Display Systems Inc All rights reserved Printed copies are Uncontrolled unless clearly marked as a Controlled document User is responsible for verifying d...

Страница 2: ...T NETWORK CONNECTION TO POS 7 5 2 SERIAL SERVER CONNECTION TO POS 8 5 3 SERIAL SERVER CONNECTIVITY 8 5 4 VIDEO ENCODER CONNECTION TO POS VIDEO OUTPUT 9 5 5 SUPPLIED EQUIPMENT 10 5 6 DISPLAY MOUNTING O...

Страница 3: ...K OF DISPLAY 6 FIGURE 3 SYSTEM CONNECTIONS DIRECT CONNECTION TO POS 7 FIGURE 4 SYSTEM CONNECTIONS SERIAL SERVER CONNECTION TO POS 8 FIGURE 5 SERIAL SERVER BOTH ENDS 8 FIGURE 6 SYSTEM CONNECTIONS VIDEO...

Страница 4: ...30 150 A01 Order Confirmation System OCS display including instructions on the connections all cabling and any additional hardware required for installation 2 Warnings Warning This is a Class A produc...

Страница 5: ...VDC Power Wireless BLE Ibeacon Enclosure Rating IP66 IEC 60529 Construction Aluminum Steel Weight 11 6 lbs Glass Optically bonded w UV IR blocking Anti Glare AG Dimensions in 14 75w x 12 25h x 2 80d R...

Страница 6: ...The system is designed to be connected directly to the local area network LAN via a CAT5 cable connection on the rear of the unit An IP67 rated outdoor external 120 220VAC DC power supply is provided...

Страница 7: ...15VDC power supply that is connected to a 120 220VAC power provided at the point of installation The display is connected to an available port on the store network switch using the supplied CAT5 cabl...

Страница 8: ...itch as shown below Figure 4 System Connections Serial Server Connection to POS 5 3 Serial Server Connectivity If the POS system relies on connectivity directly to the order taking register then the S...

Страница 9: ...re the POS system renders the video content for the OCS display directly the video source can be streamed directly to the OCS using a digital video encoder as shown below The encoder converts the HDMI...

Страница 10: ...U Power Cable Japan PSE certified DEL PWR CD JP Power Cable Taiwan DEL PWR CD TW Note The country specific power cord is supplied with the 15X Display part number and description above It is only used...

Страница 11: ...ther type of connector on the back of the display will result in a loose connection and will void the customer s warranty Although the shielded connector is necessary it is not actually used as a shie...

Страница 12: ...shown below Figure 11 Field Connector Assembly Step 2 Next untwist the wires and place them into the correct order for 568B termination Cut the length of the wires down to approximately 13mm then ter...

Страница 13: ...connection to the display Plug the connector to the back of the display at the RJ45 receptacle Once connected screw the Connector Nut into the back of the display until it is tight Connect the 15V po...

Страница 14: ...st PC or laptop computer connect to the switch and try to ping the display Make sure to change the IP address on your PC or laptop to allow communications with the display If you cannot ping the displ...

Страница 15: ...nless clearly marked as a Controlled document User is responsible for verifying document is the current revision 9 Technical Support For technical assistance please contact Delphi Display Systems Inc...

Страница 16: ...nted copies are Uncontrolled unless clearly marked as a Controlled document User is responsible for verifying document is the current revision 11 Document Revisions Revision Date Notes Author A 7 20 2...

Отзывы: