Technical specification
TECHNICAL SPECIFICATION
Power supply
see rating plate
Max. absorbed power
in air conditioning
“
Max. absorbed power
when heating (mod. F300)
“
Refrigerating capacity*
“
Number of fan speeds
2
Max. air flow
460 m
3
/h
Dimensions of internal unit:
•
width
452 mm
•
height
800 mm
•
depth 415
mm
•
weight 35
kg
Dimensions of external unit:
•
width
465 mm
•
height
480 mm
•
depth 240
mm
•
weight 12
kg
*
Standard conditions:
Room temperature
27°C
47% relative humidity
Outside temperature
35°C
41% relative humidity
This appliance contains substances which, if liberated into the atmosphere, would damage the
ozone layer. Care should therefore be taken not to perforate the refrigerant circuit. At the end of
its working life, delivery the air conditioning unit to a special collection centre.
RECOMMENDED OPERATING
CONDITIONS
Room temperature
21 ÷ 32°C
Outside temperature
21 ÷ 43°C
ELECTRICAL CONNECTION (U.K. ONLY)
A) If your appliance comes fitted with a plug, it will incorporate a 13 Amp fuse. If it does not fit your socket, the plug should
be cut off from the mains lead, and on appropriate plug fitted, as below. warning: Very carefully dispose of the cut off
plug after removing the fuse: do not insert in a 13 Amp socket elsewhere in the house as this could cause a shock hazard.
With alternative plugs not incorporating a fuse, the circuit must be protected by a 15 Amp fuse. If the plug is a moulded-
on type, the fuse cover must be re-fitted when changing the fuse using a 13 Amp Asta approved fuse to BS 1362. In the
event of losing the fuse cover, the plug must NOT be used until a replacement fuse cover can be obtained from your nea-
rest electrical dealer. The colour of the correct replacement fuse cover is that as marked on the base of the plug.
B) If your appliance is not fitted with a plug, please follow the instructins provided below:
WARNING - THIS APPLIANCE MUST BE EARTHED
IMPORTANT
The wires in the mains lead are coloured in accordance with
the following code:
Green and yellow Earth
Blue
Neutral
Brown
Live
As the colours of the wires in the mains lead may not corre-
spond with the coloured markings identifying the terminals
in your plug, proceed as follows:
The green and yellow wire must be connected to the termi-
nal in the plug marked with the letter E or the earth symbol
or coloured green or green and yellow.
The blue wire must be connected to the terminal marked with
the letter N or coloured black.
The brown wire must be connected to the terminal marked
with the letter L or coloured red.
N
E
L
I 8-08-2001 9:30 Pagina 29
Содержание PACF400
Страница 90: ...90 3 1 I 8 08 2001 9 42 Pagina 90...
Страница 93: ...93 HELLAS F300 1 2 3 2 4 2 5 24 21 24 19 6 7 1 2 3 4 5 6 7 2 2 I 8 08 2001 9 42 Pagina 93...
Страница 94: ...94 1 2 4mm 3 6mm 17 17 13 12 15 17 1 5 6 cm 15 14 1 2 I 8 08 2001 9 42 Pagina 94...
Страница 95: ...95 HELLAS 1 l 12 6 9 1 0 STOP MANUALE 16 16 1 15 2 3 9 8 12 7 4 7 9 1 2 1 7 H I 8 08 2001 9 42 Pagina 95...
Страница 96: ...96 22 F300 I 8 08 2001 9 42 Pagina 96...
Страница 97: ...97 HELLAS 40 C FILTRETETM 1 2 F filtreteTM G 1 2 FILTRETETM 1 F 2 1 FILTRETETM 3 I 8 08 2001 9 43 Pagina 97...
Страница 98: ...98 STOP timer 11 F300 I 8 08 2001 9 43 Pagina 98...