DeLonghi PAC C100 Скачать руководство пользователя страница 6

9

GB

Operation

TURNING THE APPLIANCE ON

Plug into the outlet and check the black cap is fully inserted.
Two lines appear on the display indicating that the appliance is in
stand-by. 
Press the 

ON/STAND-BY

button (

A

). When turned on, the air conditioner

starts operating in the same mode as when it was turned off. 
Press the 

MODE

button (

B

) until the light corresponding to the desired

mode lights up: 

Light (

Q

)

AIR-CONDITIONING MODE

Light (

P

)

DEHUMIDIFYING MODE

Light (

O

)

:   

FAN MODE

AIR CONDITIONING MODE

Ideal for hot muggy weather when you need to cool and dehumidify
the room. To set this mode:   press the + (

E

) or - (

F

) buttons until the desi-

red temperature is displayed.
Then select the fan speed by pressing the “

FAN

” button (

C

) until the

light corresponding to the required fan speed lights up:

HIGH

:

MAXIMUM SPEED

to achieve the target temperature as rapidly

as possible

MED

:

MEDIUM SPEED

reduces noise levels while maintaining a comfor-

table temperature

LOW

:

LOW SPEED

for silent operation and maximum energy efficiency

AUTO

:

AUTO

: the appliance automatically selects the most suitable

fan speed in relation to the temperature set on the digital
display and current room temperature.

The most suitable temperature for the room during the summer varies
from 75°F to 81°F (24 to 27°C). You are recommended, however, not to
set a  temperature much below the outdoor temperature

DEHUMIDIFYING MODE

Ideal to reduce room humidity (spring and autumn, damp rooms, rainy
periods, etc). In dehumidifying mode, the appliance 

MUST 

be set-up in

the same way as for air conditioning, with the air exhaust hose atta-
ched to enable the moisture to be discharged outside.
When the dehumidifying mode is selected, the light (

P

) comes on and

“       ” appears on the display.
At the same time, the 

AUTO

fan light (

N

) comes on.

In this mode, fan speed is selected automatically by the appliance and
cannot be set manually. 

FAN MODE

The unit operates without cooling or dehumidifying.  This mode provides
ventilation only. When using the appliance in this mode, the air exhaust
hose does not need to be connected. Adjust fan speed by pressing the

FAN

” button (

C

) as described for the air-conditioning mode. 

In this mode,

AUTO

speed cannot be selected. 

The fan speed selected will be displayed.

 

 

Содержание PAC C100

Страница 1: ...cleaning or maintenance operations always unplug the unit from the outlet Do not pull on or place strain on the power cord when moving the appliance The appliance should not be installed where the at...

Страница 2: ...ithout allowing the unit this time 6 24 hours the unit may function for only a short time and then the compressor will break down from lack of oil ELECTRICAL CONNECTIONS Before plugging the appliance...

Страница 3: ...NG WITHOUT INSTALLATION NOTE Keep the air hoses as short and free of curves as possible to avoid con strictions FOR OPTIMAL RESULTS SET UP IN A DOU BLE HUNG WINDOW 1 Place the bracket in the window si...

Страница 4: ...fig A page 6 Fit the end of the hose 11 to the wall flange 10 as shown in fig G When the hose 11 is not connected the drilled hole can be closed with the flange cap 10 For models supplied only with t...

Страница 5: ...y Displays the temperature values set and the programmed operating time H Timer in operation indicator light I L M N Fan speed lights and AUTO lights O Fan mode light P Dehumidifying mode light Q Air...

Страница 6: ...UTO the appliance automatically selects the most suitable fan speed in relation to the temperature set on the digital display and current room temperature The most suitable temperature for the room du...

Страница 7: ...press the timer button D again How to program delayed shutdown Delayed shutdown can be programmed in any operating mode air conditioning dehumidifying fan Press the TIMER button D The last timer setti...

Страница 8: ...TING OR REPLACING THE BATTERIES Remove the cover on the rear of the remote control Replace the old batteries with two new R03 AAA 1 5V batteries insert ing them correctly see the instruc tions inside...

Страница 9: ...bject to the follow ing two conditions 1 this device may not cause harmful interference and 2 this device must accept any interference received including interference that may cause undesired operatio...

Страница 10: ...f the timer A countdown of the time left is displayed on the remote control display and the light H flashes on the air conditioner display At the end of the set time the appliance switches off automat...

Страница 11: ...om from direct exposure to the sun by partially closing curtains and or blinds to help the appliance run more efficiently Never rest objects of any kind on the air conditioner Tips close doors and win...

Страница 12: ...st filter every week of operation The filter is housed in the intake grille To clean the filters proceed as follows 1 Remove the dust filter by extracting it upwards figure G 2 Use a vacuum cleaner to...

Страница 13: ...lose the window Eliminate the heat source Connect the exhaust hose Clean or replace the filters Clean or replace the filter Bad odor in the room The filter is clogged The air conditioner does not oper...

Страница 14: ...f refrigerant should be performed by a technical service centre appointed by the manufacturer only The appliance should be disposed of by a specialist centre appointed by the manu facturer only ELECTR...

Страница 15: ...lities on our part We do not authorize any other person or company to assume for us any liability in connection with the sale or use of our AIR CONDITIONER This war ranty shall not apply to any AIR CO...

Отзывы: