16

Troubleshooting

PROBLEM CAUSE 

REMEDY

The air 
conditioning unit
does not start.

No electricity.

It is not plugged into the outlet.

The safety device of the plug has 
tripped.

The internal safety device has tripped.

Restore electricity.

Plug into the outlet.

Reset the safety plug.

Wait 30 minutes, if the pro-
blem persists, contact your
service center.

The air 
conditioning unit
works for a short
time only.

The air exhaust hose has a constriction.

The air exhaust hose is blocked.

There are  tight bends in the air exhaust
hose.

Position the exhaust hose
correctly.

Check there are no 
obstacles Obstructing air
discharge. 

Eliminate the tight bends.

The air 
conditioner
works, but does
not cool the
room.

Window open.

There are heat sources in the room
(lamps, etc.).

The exhaust hose is detached.

Air filters clogged.

Close the window.

Eliminate the heat source.

Connect the exhaust hose.

Clean or replace the filters.

Clean or replace the filter.

Bad odor in the
room.

The filter is clogged.

The air 
conditioner does
not operate for
about 3 minutes
after turning it on.

The internal compressor safety device
prevents the appliance from being
restarted until three minutes have ela-
psed since it was last turned off.

Wait. This delay is part of
normal operation. 

/ PF/

appears on the
display.

The appliance has a self diagnosis
system to identify a number of malfunc-
tions.

See the self-diagnosis chap-
ter.

NOTE:

NEVER TRANSPORT OR TURN THE APPLIANCE UPSIDE DOWN OR ON ITS SIDE. IF THIS OCCURS,
WAIT 6 HOURS BEFORE TURNING THE APPLIANCE ON, 24 HOURS IS RECOMMENDED. After the
unit has been on its side, oil needs to return to the compressor to ensure proper function.  With-
out allowing the unit this time (6-24 hours) the unit may function for only a short time, and then
the compressor will break down from lack of oil. 

TROUBLESHOOTING

n g

Содержание PAC C100

Страница 1: ...cleaning or maintenance operations always unplug the unit from the outlet Do not pull on or place strain on the power cord when moving the appliance The appliance should not be installed where the at...

Страница 2: ...ithout allowing the unit this time 6 24 hours the unit may function for only a short time and then the compressor will break down from lack of oil ELECTRICAL CONNECTIONS Before plugging the appliance...

Страница 3: ...NG WITHOUT INSTALLATION NOTE Keep the air hoses as short and free of curves as possible to avoid con strictions FOR OPTIMAL RESULTS SET UP IN A DOU BLE HUNG WINDOW 1 Place the bracket in the window si...

Страница 4: ...fig A page 6 Fit the end of the hose 11 to the wall flange 10 as shown in fig G When the hose 11 is not connected the drilled hole can be closed with the flange cap 10 For models supplied only with t...

Страница 5: ...y Displays the temperature values set and the programmed operating time H Timer in operation indicator light I L M N Fan speed lights and AUTO lights O Fan mode light P Dehumidifying mode light Q Air...

Страница 6: ...UTO the appliance automatically selects the most suitable fan speed in relation to the temperature set on the digital display and current room temperature The most suitable temperature for the room du...

Страница 7: ...press the timer button D again How to program delayed shutdown Delayed shutdown can be programmed in any operating mode air conditioning dehumidifying fan Press the TIMER button D The last timer setti...

Страница 8: ...TING OR REPLACING THE BATTERIES Remove the cover on the rear of the remote control Replace the old batteries with two new R03 AAA 1 5V batteries insert ing them correctly see the instruc tions inside...

Страница 9: ...bject to the follow ing two conditions 1 this device may not cause harmful interference and 2 this device must accept any interference received including interference that may cause undesired operatio...

Страница 10: ...f the timer A countdown of the time left is displayed on the remote control display and the light H flashes on the air conditioner display At the end of the set time the appliance switches off automat...

Страница 11: ...om from direct exposure to the sun by partially closing curtains and or blinds to help the appliance run more efficiently Never rest objects of any kind on the air conditioner Tips close doors and win...

Страница 12: ...st filter every week of operation The filter is housed in the intake grille To clean the filters proceed as follows 1 Remove the dust filter by extracting it upwards figure G 2 Use a vacuum cleaner to...

Страница 13: ...lose the window Eliminate the heat source Connect the exhaust hose Clean or replace the filters Clean or replace the filter Bad odor in the room The filter is clogged The air conditioner does not oper...

Страница 14: ...f refrigerant should be performed by a technical service centre appointed by the manufacturer only The appliance should be disposed of by a specialist centre appointed by the manu facturer only ELECTR...

Страница 15: ...lities on our part We do not authorize any other person or company to assume for us any liability in connection with the sale or use of our AIR CONDITIONER This war ranty shall not apply to any AIR CO...

Отзывы: