background image

22

"SLEEP" signal lamp

Min. speed signal lamp

Air-cooling signal lamp

ON timer signal lamp

CONTROL PANEL

ON/OFF Timer key

"SLEEP" key

SETTING THE TIMER

Ther programmer/timer, like all clocks, must be
set to the exact time. If for example it is 4.00 p.m.
(16.00), turn the dial in a clockwise direction
(following the direction of the arrow) until the
number 16 is lined up with the tringular pointer
(the arrows indicates 4:00 p.m. approximately).

N.B.: Never turn the dial in anti-clockwise direction!
The timer is in effect, an electric clock and works
only if the plug is connected to the power supply.
Whenever the plug is disconnected or there is a
power failure, the programmer stops (the clock is
then "slow" and must be re-set.

Select operation "

with timer

" or "

without timer

".

21

20

19

16

Example: from 7 p.m. to 9 p.m.

The air-conditioner will now switch on each day at
the selected times.

N.B.: If you wish to override the programmed

operating times, simply press the ON/OFF
timer key (the timer signal lamp ON will go
out).

Timer

Thermostat

slider

Air-cooling

signal lamp

ON/OFF key

Automatic function signal lamp

Signal lamp indicating 3 min. wait (flashing) or
working appliance (on continuously)

Signal lamp mains (continuous light) or
malfunction (flashing light)

Fan speed key

Air-cooling key

Max. speed signal lamp

Pointer

21

20

19

16

Function

O

FF

ON

OF

F

OPERATION WITH TIMER

1) Select the desired function as shown in the

chart overleaf.

2) Press the TIMER key, the "TIMER ON" signal

lamp will come ON.

3) Make sure that the timer indicates the correct

time (see instructions on setting).

4) Set the operating times by pushing out the

notches on the dial corresponding to the
period required (each notch represent 15
mins).

OPERATIONG WITHOUT TIMER

1) Press the TIMER ON key again, the TIMER ON

signal lamp will go out.

2) Select the desired function as shown in the

chart on page. 9.

For technical reasons, the temperature is not
expressed in degrees but by a line increasing in
thickness. We therefore recommend that when
starting up the appliance, the thermostat be
turned to maximum (thick green line = maximum
cold). When the desired temperature has been
reached move the thermostat slider slowly away
from the maximum cold position until the
appliance is switched off by operation of the
thermostat. In this way the appliance has been
programmed with the exact temperature degree
required, which is then maintained automatically
by the thermostat.

Содержание PAC 36

Страница 1: ...15 Instructions for use Air conditioner PAC 36...

Страница 2: ...tion This function activates a program studied and designed to increase comfort during sleeping hours The program not only ensures perfect silence from both the internal and external units but also co...

Страница 3: ...L UNIT Condensation discharge tube Castors Power cable Rear panel Carrying handle Removable filter Power cable Air intake grille INTERNAL UNIT Connection hose Air outlet grid Control panel Control pan...

Страница 4: ...Support belt with hook Frame for connector hose Castor stop Condensation drainage coupling Castors for external unit and washers This appliance is fitted with a special HE High Efficiency system for...

Страница 5: ...n position Repeat this operation for the second union The path of the connector hose should be as straight as possible without sharp curves or kinks 5 Detach the condensation hose from its coupling 6...

Страница 6: ...me level as the internal unit provided that the difference in height between the two units does not exceed 1 5 m Theintakeandoutletventsmustnotbeobstructed Leave a space of at least 6 cm between the r...

Страница 7: ...ioned are closed except for temporary installation inwhichcaseawindowmustbeleft partially open ELECTRICAL CONNECTIONS Beforepluggingtheunitintothemains checkthe following the mains voltage must be the...

Страница 8: ...p Signal lamp indicating 3 min wait flashing or working appliance on continuously Signal lamp mains continuous light or malfunction flashing light Fan speed key Air cooling key Max speed signal lamp P...

Страница 9: ...and the AUTO and MAX lamps will go out to modify the power press the relevant key AIR CONDITIONING TheSLEEPwarninglampremainson Anautomatic program is enabled The appliance is activated at minimum sp...

Страница 10: ...m perature of the water should not exceed 40 C Allow the filter to dry before replacing it in the appliance AT THE BEGINNING OF THE SEASON Check that the power cord and the plug are undamagedandthatth...

Страница 11: ...ditioner functions for a brief period only The pilot lamp flashes the safety float has switched the appliance off because the condensation tray inside the appliance is full the control circuit board i...

Отзывы: