26
CONTROL PANEL
NB.
For technical reasons, the temperature is not expressed in degrees but by a line increasing in thickness.
We therefore recommend that when starting up the appliance, the thermostat be turned to maximum
(thick green line = maximum cold, thick pink line = maximum hot). When the desired temperature has
been reached, move the cursor slowly away from the maximum cold or maximum hot position until the
appliance is switched off by operation of the thermostat. In this way the appliance has been programmed
with the exact temperature degree required, which is then maintained automatically by the thermostat.
This appliance is fitted with a safety device that blocks its operation if at least 3 minutes have not
elapsed from when it was last switched off.
SETTING THE TIMER
The programmer/timer, like all clocks, must be set to the
exact time. If for example it is 4.00 pm. (16.00), turn the
dial in a clockwise direction (following the direction of the
arrow) until the number 16 is lined up with the triangular
pointer (the arrows indicates 4:00 P.M. approximately ).
N.B.:
Never turn the dial in an anti-clockwise direction!
The timer is in effect, an electric clock and works only if the
plug is connected to the power supply. Whenever the
plug is disconnected or there is a power failure, the
programmer stops (the clock is then “slow”) and must be
re-set.
The Pinguino can be used for either AIR-COOLING or
HEATING.
The unit can be used in either programmed or non-
programmed mode.
PROGRAMMED MODE
1) Select the desired function as shown in the chart
overleaf.
2) Press the TIMER key, the “TIMER ON” signal light will
come ON.
3) Make sure that the timer indicates the correct time (see
instructions on setting).
4) Set the operating times by pushing out the notches on
the dial corresponding to the period required (each
notch represents 15 mins.)
The unit will now switch on and off each day at the
selected times.
N.B.:
To override the programmed operating times, simply
press the ON/OFF key (the timer signal lamp ON will go
out)
NON-PROGRAMMED MODE
1) Press the TIMER ON key again, the TIMER ON signal lamp
will go out).
2) Select the desired function as shown in the chart on pg. 27.
21
20
19
16
21
20
19
16
Funzionamento
Operating time
THERMOSTAT
TIMER ON
MEMO CONTROL
Timer
Air-cooling
signal lamp
Heating signal
lamp
Thermostat
cursor
ON/OFF Timer key
ON timer signal lamp
Automatic
position key
Button ON/OFF
Plot lamp mains (continuous light)
or malfunction (flashing light)
Signal lamp indicating 3 min.wait (flashing)
or air-cooling (on continuously)
Heating key
Temperature OK signal lamp
Automatic heating signal lamp
Air-cooling key
Max. speed warning light
Min. speed warning light
Economic heating signal lamp
Max. heat warning light
Automatic air-cooling signal lamp