24
PREPARING THE UNIT FOR USE
1) For permanent installation, place the appliance near the wall or window outlet. Make sure it is standing
on a level surface and fit the special shock absorbers/castor stops underneath the castors.
2) The exhaust hose can be compressed or extended between 500 mm. and 1400 mm., but is best used
at minimum length.
Never stretch the hose.
HOW TO PREPARE WATER CONTAINER
Use only clean, salt-free tap water. The water is essential for the air cooling operation and is discharged
in the form of steam through the exhaust outlet. A container full of water lasts for a period that depends
on a number of conditions such as temperature, humidity, insulation, exposure of the room, number of
people present, etc. On average it will last approximately 7 to 10 hours.
When the container is empty, the appliance automatically changes function from water to air. At the same
time, the quantity of air discharged from the rear hose will increase.
Open the water container compartment
door, tip the container forwards and lift
up to remove.
After filling, replace the extendable tube,
screw the cap on tightly and return the
container to its place, making sure the
word FRONT is facing out.
Remove the cap, pull out the extendable
tube and fill the container, standing it on
the floor.
During “water condensation” cooling function and in particularly quiet surroundings (eg. bedroom), a
slight gurgling noise may be heard. This may be regarded as perfectly normal.
Warning:
Do not use water containing salt, eg. seawater or water treated using softening systems that
utilize kitchen salt.