27

HOW TO START UP THE CONDITIONER
(see control panel on the opposite page)

The appliance comes

 

on

If not, refer to pg. 30

To switch off the appliance,

press the 

Power

 push-button.

Plug the appliance into the mains.
The signal lamp will come on 

 .

Press the key for the function required:

AIR-COOL. KEY

= Air-conditioning

HEAT. KEY

= Heating

AUTO. KEY

= Automatic climatization

(air-conditioning or heating)

  AIR-CONDITIONING

  HEATING

AUTOMATIC

The 

Min.

  speed warning

light comes on.

The 

Econ

  signal lamp

comes on (economic elec-
tric heating 1300W)

The appliance automati-
cally selects

 heating

 (when

it is too cold), 

air-condi-

tioning

 (when it is too hot)

or 

remains switched off

Move the cursor to maxi-
mum hot position. The heat-
ing signal lamp comes on.
(When the room tempeture
has reached the desired
level, move the sliding ther-
mostat control gradually to
the  min. position: the unit
switches off and the heat-
ing signal lamp start to
flash).

Press the “Air-conditioning”
key again to increase fan
speed. The Max. speed
warning light comes on.

Press the “Heating” key
again to obtain Max. power.
The Max. heat warning light
comes on.

One of the signal lamps will
come on, depending on the
function selected by the
microcomputer.

Select either the 

“Programmed” 

or 

“Non-programmed” 

mode

(see pg. 26)

Press the ON/OFF key.

The function signal lamps flash and the 

 signal lamp goes

out.

Move the cursor to maxi-
mum cold position. The air-
cooling signal lamp comes
on. (When the room
tempeture has reached the
desired level, move the slid-
ing thermostat control
gradually to the  min. posi-
tion: the unit switches off
and the conditioning sig-
nal lamp start to flash).

Содержание PAC 30

Страница 1: ...time and effort to read this manual carefully Becoming familiar with the Pinguino is an essential step if you are to benefit fully from its exceptional qualities during both installation and actual us...

Страница 2: ...AC 30 ELECTRONIC can also be used as a heater during the winter months The PAC 30 ELECTRONIC sets the temperature automatically TECHNICAL DATA Tab 1 IDEAL OPERATING CONDITIONS AIR CONDITIONING FUNCTIO...

Страница 3: ...trol panel Programmer timer Water container Castors Castor stops Water collecting tray Water container compartment door Air filter Air intake grid Warranty envelope Exhaust hose compartment Power cabl...

Страница 4: ...OF ACCESSORIES Tab 4 PARTS SUPPLIED DESCRIPTION Exhaust hose Stopper flange Castor stop De scaling fluid Window nozzle Suction cup set 1 1 2 1 1 1 ACCESSORY CHECK Check that all parts listed in Table...

Страница 5: ...safety switch Air entering the room through door and window cracks is normally sufficient If necessary leave a door slightly ajar a gap of approx 1 cm is adequate The unit can also be used as a tempo...

Страница 6: ...arge hose to be installed ELECTRICAL CONNECTIONS The mains supply suitable for domestic electrical appliances must correspond to the power requirements of the air conditioner see rating label Check th...

Страница 7: ...f the room number of people present etc On average it will last approximately 7 to 10 hours When the container is empty the appliance automatically changes function from water to air At the same time...

Страница 8: ...exception of the partially opened window necessary for temporary installation the room is well shaded from direct sunlight by drawing curtains and or partially lowering blinds or shutters to avoid ex...

Страница 9: ...wer failure the programmer stops the clock is then slow and must be re set The Pinguino can be used for either AIR COOLING or HEATING The unit can be used in either programmed or non programmed mode P...

Страница 10: ...Theheat ing signal lamp comes on When the room tempeture has reached the desired level movetheslidingther mostat control gradually to the min position the unit switches off and the heat ing signal la...

Страница 11: ...air conditioner in oily or sulphurous atmospheres or near sources of heat Before moving the air conditioner empty the water from the collecting tray through the drainage tube Never place hot or heavy...

Страница 12: ...result to paintwork and plastic CLEANING COLLECTING TRAY The collecting tray should be cleaned at least once a month to prevent dirt from accumulating after prolonged use 1 Switch off the appliance an...

Страница 13: ...thermostat on the heating element has been activated to reset the unit disconnect it from mainsforafewminutes eliminatethe cause of overheating and then re connect check whether discharge of air to o...

Страница 14: ...nit c Leave the air conditioner to operate for about half an hour d Drain away all the fluid left in the tray and rinse thoroughly The drainage tube should be open and the appliance switched on during...

Отзывы: