19
The burner are conceived in such a
way so as not to require the regulation
of the primary air.
OPERATIONS TO BE PERFORMED WHEN SUBSTITUTING
THE INJECTORS (Rapid, triple ring and dual burners
)
✓
Remove the gratings and the burner covers;
✓
Using a wrench substitute the nozzle injectors “J” (figs. 2.10a - 2.10b - 2.10c) with
those most suitable for the kind of gas for which it is to be used.
Fig. 2.10a
Fig. 2.10b
Fig. 2.10c
INJECTORS TABLE
Rapid
burner
Triple ring
burner
DUAL
burner
J
Injector for inner crown
J
Injectors for
outer crowns
J
J
BURNERS
NOMINAL POWER
BTU/hr
REDUCED POWER
BTU/hr
LP/PROPANE
11” W.C.P.
NATURAL GAS
4” W.C.P.
Ø injector
[1/100 mm]
By-pass
[1/100 mm]
Ø injector
[1/100 mm]
By-pass
[1/100 mm]
Rapid (R)
10000
2000
94
42
155
adjustable
Triple ring (TC)
12000
5000
102
65
170
adjustable
Griddle
12000
5000
105
65
175
adjustable
Dual (D)
Inner crown
2800
for NATURAL GAS (*)
3500
for LP/PROPANE GAS (*)
1000 (*)
55
(no. 1 central)
27
80
(no. 1 central)
adjustable
Outer crowns
16000
for NATURAL GAS (#)
15000
for LP/PROPANE GAS (#)
6500
for NATURAL GAS (#)
4500
for LP/PROPANE GAS (#)
72
(no. 2 outer)
60
130
(no. 2 outer)
adjustable
(*) Power calculated only with inner crown operating
(#) Power calculated with inner and outer crowns operating