background image

PIN  TALK

There are two types of contact pins - uninsulated, which were
provided with your meter, and insulated. When using uninsulated
pins, push them in to the wood to their full length, if possible.
This will give you the highest measured reading. Insulated pins
read only at the tip and can be driven to a desired depth to
gather shell and core (gradient) information. Additional types
and lengths of both the insulated and uninsulated pins are
available for specific applications.

5

TEMPERATURE

CORRECTION TABLE

WOOD
TEMP.

METER READINGS 

˚C

˚F

6

7

10

15

20

25

30

35

40

50

60

-20

0

9

11

15

22

31

38

45

53

-10

20

8

10

14

20

28

34

40

47

55

5

40

7

8

12

18

24

30

36

42

48

15

60

6

7

11

16

21

27

32

38

43

54

30

80

6

7

9

14

19

23

28

33

38

47

55 

40

100

5

6

8

12

17

21

25

29

34

42

50

50

120

5

5

7

11

15

19

22

26

30

38

44 

60

140

4

5

7

10

14

17

20

23

27

34

40

70

160

4

4

6

9

12

15

18

21

24

30

36

80

180

3

4

5

8

11

13

16

19

22

27

33

95

200

3

4

5

7

10

12

14

17

19

24

28

105

220

2

3

4

6

9

11

13

15

17

21

26

Moisture content values shown in blue are only qualitative,
since they are above the fiber saturation point.

The temperature correction values shown in this chart have
been rounded for easy reference. 

www.

.com

[email protected]

1.800.561.8187

Содержание J-Lite

Страница 1: ...J Lite o w n e r s m a n u a l W H E N A C C U R A C Y I S T H E P O I N T TM www com information itm com 1 800 561 8187...

Страница 2: ...tion 3 Taking a Reading 3 Understanding Your Readings 4 Meter Readings 5 Temperature Correction Table 5 Pin Talk 6 Care of Your Meter 6 Service For Your Meter 7 Warranty Species Correction Chart on Ba...

Страница 3: ...ilt in calibration check hTemperature stable circuit hErgonomic case design hEasy one hand operation hIncludes 1 9 Volt Battery hIncludes sturdy carrying case hThree year warranty hOver fifty years of...

Страница 4: ...rmation under the Pin Talk section hRemove the protective cover to expose the pins Check that the contact pins are firmly hand tightened hAlign the contact pins parallel to the grain pushing them thei...

Страница 5: ...Between 17 1 and 18 0 19 Between 18 1 and 19 0 20 Between 19 1 and 20 0 Blinking 20 and 25 Between 20 1 and 22 5 25 Between 22 6 and 25 0 Blinking 25 and 30 Between 25 1 and 27 5 30 Between 27 6 and...

Страница 6: ...EMP METER READINGS C F 6 7 10 15 20 25 30 35 40 50 60 20 0 9 11 15 22 31 38 45 53 10 20 8 10 14 20 28 34 40 47 55 5 40 7 8 12 18 24 30 36 42 48 15 60 6 7 11 16 21 27 32 38 43 54 30 80 6 7 9 14 19 23 2...

Страница 7: ...oblem hThere is no need to call us for a return authorization number if you are within the U S Customers outside the U S must contact us for more specific instructions prior to returning a meter hIncl...

Страница 8: ...7 19 21 23 25 26 CEDAR INCENSE 7 8 9 5 10 5 12 5 15 17 19 21 23 25 CHERRY 8 9 10 11 13 5 15 5 18 20 22 24 26 COTTONWOOD 6 7 5 8 5 9 5 12 14 15 17 19 5 21 23 CYPRESS 7 8 9 10 12 14 16 18 19 5 21 5 23 5...

Страница 9: ...10 12 14 16 18 20 22 5 25 MERANTI DARK RED 8 5 9 5 10 5 11 5 12 5 16 18 20 5 22 5 24 5 26 5 OAK RED 7 8 9 10 12 14 16 18 20 22 24 OAK WHITE 7 8 8 5 9 5 11 5 13 5 15 17 18 5 20 22 PECAN 6 5 8 9 5 11 1...

Страница 10: ...K 7 8 8 5 9 11 12 14 15 17 18 5 20 VIROLA 6 5 7 8 9 11 12 5 14 16 18 18 5 20 5 WALNUT BLACK 7 5 8 5 9 5 10 5 12 5 14 5 16 18 20 22 23 5 Meter readings taken with 26 E 2 pin electrode Do not apply 2 pi...

Отзывы: