J-LITE FEATURES

h

Resistance technology recognized worldwide as the most

accurate method for measuring moisture

h

6% to 30% moisture range

h

LED readout

h

Proven microcontroller circuit for increased reliability and

accuracy

h

Built-in calibration check

h

Temperature-stable circuit

h

Ergonomic case design

h

Easy one-hand operation

h

Includes (1) 9-Volt Battery

h

Includes sturdy carrying case

h

Three-year warranty

h

Over fifty years of proven quality, accuracy and service

#2497A-100 contact pins
with 5/16” penetration

Read Button

Calibration
Check Button

#

LED

Readout

%

External

Connector

@

!

D E L M H O R S T   J - L I T E

2

www.

.com

[email protected]

1.800.561.8187

Содержание J-Lite

Страница 1: ...J Lite o w n e r s m a n u a l W H E N A C C U R A C Y I S T H E P O I N T TM www com information itm com 1 800 561 8187...

Страница 2: ...tion 3 Taking a Reading 3 Understanding Your Readings 4 Meter Readings 5 Temperature Correction Table 5 Pin Talk 6 Care of Your Meter 6 Service For Your Meter 7 Warranty Species Correction Chart on Ba...

Страница 3: ...ilt in calibration check hTemperature stable circuit hErgonomic case design hEasy one hand operation hIncludes 1 9 Volt Battery hIncludes sturdy carrying case hThree year warranty hOver fifty years of...

Страница 4: ...rmation under the Pin Talk section hRemove the protective cover to expose the pins Check that the contact pins are firmly hand tightened hAlign the contact pins parallel to the grain pushing them thei...

Страница 5: ...Between 17 1 and 18 0 19 Between 18 1 and 19 0 20 Between 19 1 and 20 0 Blinking 20 and 25 Between 20 1 and 22 5 25 Between 22 6 and 25 0 Blinking 25 and 30 Between 25 1 and 27 5 30 Between 27 6 and...

Страница 6: ...EMP METER READINGS C F 6 7 10 15 20 25 30 35 40 50 60 20 0 9 11 15 22 31 38 45 53 10 20 8 10 14 20 28 34 40 47 55 5 40 7 8 12 18 24 30 36 42 48 15 60 6 7 11 16 21 27 32 38 43 54 30 80 6 7 9 14 19 23 2...

Страница 7: ...oblem hThere is no need to call us for a return authorization number if you are within the U S Customers outside the U S must contact us for more specific instructions prior to returning a meter hIncl...

Страница 8: ...7 19 21 23 25 26 CEDAR INCENSE 7 8 9 5 10 5 12 5 15 17 19 21 23 25 CHERRY 8 9 10 11 13 5 15 5 18 20 22 24 26 COTTONWOOD 6 7 5 8 5 9 5 12 14 15 17 19 5 21 23 CYPRESS 7 8 9 10 12 14 16 18 19 5 21 5 23 5...

Страница 9: ...10 12 14 16 18 20 22 5 25 MERANTI DARK RED 8 5 9 5 10 5 11 5 12 5 16 18 20 5 22 5 24 5 26 5 OAK RED 7 8 9 10 12 14 16 18 20 22 24 OAK WHITE 7 8 8 5 9 5 11 5 13 5 15 17 18 5 20 22 PECAN 6 5 8 9 5 11 1...

Страница 10: ...K 7 8 8 5 9 11 12 14 15 17 18 5 20 VIROLA 6 5 7 8 9 11 12 5 14 16 18 18 5 20 5 WALNUT BLACK 7 5 8 5 9 5 10 5 12 5 14 5 16 18 20 22 23 5 Meter readings taken with 26 E 2 pin electrode Do not apply 2 pi...