METER READINGS
If the LED displays:
The %MC is:
Blinking 6%
Below 5.5%
6%
Between 5.5 and 6.0
7%
Between 6.1 and 7.0
8%
Between 7.1 and 8.0
9%
Between 8.1 and 9.0
10%
Between 9.1 and 10.0
Blinking 10% and 12%
Between 10.1 and 11.0
12%
Between 11.1 and 12.0
Blinking 12% and 15%
Between 12.1 and 13.5
15%
Between 13.6 and 15.0
Blinking 15% and 17%
Between 15.1 and 16.0
17%
Between 16.1 and 17.0
Blinking 17% and 19%
Between 17.1 and 18.0
19%
Between 18.1 and 19.0
20%
Between 19.1 and 20.0
Blinking 20% and 25%
Between 20.1 and 22.5
25%
Between 22.6 and 25.0
Blinking 25% and 30%
Between 25.1 and 27.5
30%
Between 27.6 and 30.0
Blinking 30%
Above 30%
The J-Lite can be used to test more than just wood. It will also
give a relative reading on plywood, OSB, particleboard and MDF
or can be fitted with a 26-ES slide hammer for specific
applications. Call Delmhorst at 800-222-0638 or e-mail
[email protected] for information on how to interpret the
readings for other materials.
4
www.
.com
1.800.561.8187