background image

Filter Pump

Safety Instructions

•  ELECTRICAL SAFETY

• 

WARNING

! It is the user’s responsibility to check the following:

•  Check all electrical equipment and appliances to ensure that they are safe before using. Inspect power supply leads, plugs and    

 

all electrical connections for wear and damage. 

• 

WARNING

The pump must be supplied through a Residual Current device (RCD) having a rated residual operating current  

 

 

not exceeding 30mA.

•  Dellonda recommend that an 

RCD

 (Residual Current Device) is used with all electrical products. If the product is used in the course of business 

duties, it must be maintained in a safe condition and routinely 

PAT

 (Portable Appliance Test) tested.

•  Electrical safety information, it is important that the following information is read and understood.

•  Ensure that the insulation on all cables and on the appliance is safe before connecting it to the power supply. 

•  Regularly inspect power supply cables and plugs for wear or damage and check all connections to ensure that they are secure.

• 

Important

: Ensure that the voltage rating on the appliance suits the power supply to be used and that the 

plug is fitted with the correct fuse - see 

fuse rating in these instructions.

• 

DO NOT

 pull or carry the appliance by the power cable.

• 

DO

 

NOT

 pull the plug from the socket by the cable. 

• 

DO NOT

 use worn or damaged cables, plugs or connectors. Ensure that any faulty item is repaired or is 

 

replaced immediately by a qualified electrician.

• 

This product is fitted with a 

BS

1363/A 13 Amp 3 pin plug. 

•   If the cable or plug is damaged during use, switch off the electricity supply and remove from use. 

• 

Ensure that repairs are carried out by a qualified electrician.

•  Replace a damaged plug with a 

BS

1363/A 13 Amp 3 pin plug. If in doubt contact a qualified electrician.

•  a) Connect the 

GREEN

/

YELLOW

 earth wire to the earth terminal ‘E’.

•  b) Connect the 

BROWN

 live wire to the live terminal ‘L’.

•  c) Connect the 

BLUE

 neutral wire to the neutral terminal ‘N’.

•  Ensure that the cable outer sheath extends inside the cable restraint and that the restraint is tight. 

• 

WARNING

! The mains cable can not be replaced. If it is damaged the appliance should be scrapped.

• 

Dellonda recommend that repairs are carried out by a qualified electrician.

•  GENERAL SAFETY

•  DO NOT 

connect to the mains supply with wet hands or while standing in water.

•  Mains supply must be protected by a 

RCD

, see above.

• 

DO

 

NOT

 use a damaged or frayed mains cable.

• 

WARNING

! The pump must be installed at least 2m from the pool.

• 

WARNING

! The pump must be fixed to the ground or a suitable stable pedestal, using Ø5mm screws, to prevent accidental falling.

• 

WARNING

! Filter pump is not to be used by children. Adult assembly and operation only.

• 

DO

 

NOT

 bury the mains cable. Locate it where it will not be damaged by lawn mowers, hedge trimmers and other garden equipment.

•  Ensure before each use of the pump, that all clamps are tightened and that all hoses are properly connected.

• 

WARNING

DO

 

NOT

 use this filter pump to vacuum the pool.

• 

WARNING

! This filter pump is designed 

ONLY

 for use with storable pools. It must not be used for permanently installed pools.  

 

 

Improper use will cause overheating and the motor to be damaged.

• 

WARNING

! To avoid overheating of the pump motor, make sure the pump is pumping water. Never allow to run dry.

• 

WARNING

! Air in the system will make the pump race and will cause damage to the pump. Refer to Operation section. 

•  This product can be used by children aged from 8 years and above and persons with reduced physical, sensory or mental capabilities  

 

or lack of experience or knowledge if they have been given supervision or instruction concerning use of the appliance in a safe way  

 

and understand the hazards involved. Children shall not play with the appliance. Cleaning and user maintenance shall not be made by  

 

children without supervision.

• 

WARNING

! The pump must not be used when people are in the water.

•  The maximum total head is 0.9m. 

 

Recommended fuse rating

13 Amp

Содержание DL19

Страница 1: ...dard this product will if used according to these instructions and properly maintained give you years of trouble free performance www dellonda co uk Dellonda 10ft Super Steel Swimming Pool with Filter...

Страница 2: ...height 4383L 1158gal Assembled dimension 300 x 76cm Supplied with 300gal h filter pump and patch repair kit DL20 Easy set up with no tools required Anti corrosion steel structure and triple layered P...

Страница 3: ...refresh this knowledge regularly This can make a lifesaving difference in the event of an emergency DO NOT use the swimming pool when using alcohol or medication that may impair your ability to safely...

Страница 4: ...tup Step1 ACCOUNT FOR ALL PARTS Remove all the parts from the carton s and place them on the ground in the location where they are to be assembled Check each part according to CONTENTS Make sure all t...

Страница 5: ...o the drain outlet by turning connector in a clockwise direction Step6 Open the outlet plug on the inside of the pool and the water will begin to drain immediately Step7 Disconnect the hose and draina...

Страница 6: ...and evenly poured into pool water from various locations around the pool perimeter DANGER NEVER add water to chemicals INSTEAD always add chemicals to water Also never mix separate chemicals together...

Страница 7: ...ris in water Bathers are not cleaning their feet prior to entering pool Adjust pH Check with a swimming pool supply retailer for correct water treatment Ensure proper chlorine level Clean or replace y...

Страница 8: ...o the live terminal L c Connect the BLUE neutral wire to the neutral terminal N Ensure that the cable outer sheath extends inside the cable restraint and that the restraint is tight WARNING The mains...

Страница 9: ...lockwise the air purge cover P1 Connect the mains supply after ensuring that all electrical and safety instructions have been carried out refer to Electrical and General safety sections above Operate...

Страница 10: ...y debris from filter net at pool wall Seek expert help Environment Protection and Waste Protection and Electrical Equipment Regulations WEEE Recycle unwanted packaging materials When this product is n...

Отзывы: