11
2.
Install the rectangle end of exhaust hose adapter into the corresponding rectangle hole in window seal-plate
assembly, fix it with screw and close the window (as Photo).
Align the 4 openings on window seal-plate with corresponding 4 openings on exhaust hose adapter and set them
together, then slide adapter downwards, to make 2 set of openings locked for 2 parts good connection.
A. Lock self-
tapping screw φ4 mm into adapter hole.
Remarks:
Slide the adapter downwards and assure the adapter installed in good position.
Lock the screw tightly to avoid fall off.
Exhaust hose can’t be bent or with flexure higher than 45 degrees, in order to keep good ventilation of
exhaust hose.
Important notes:
The exhaust hose is 280mm-1500mm long and which is determined by the specification of the
air-conditioner (s). Do not use prolonged the hose or replace it with other different hoses as this may affect the
functions of the air-conditioner. The exhaust hose must be smooth or it may lead air-conditioner overheat and trip
because exhaust hose is obstructed.
Drainage Instruction
1.
Manual drain:
When the water volume reached its alarm level in water tank, warning sounds and unit is automatically stop