8
control if the batteries have any leakage.
If you eat the liquid from the batteries, brush your teeth and see doctor. The chemicals in batteries could cause burns
or other health hazards.
Multiple Protection Functions
1.
Anti-freeze protection function
Compressor, water spraying motor will turn off when compressors running over 10 minutes and tube temperature
(Tp) is continuously
≦
35.6
℉
(
2
℃)
for 20 seconds under cooling mode, E4 will show on LED display window, the
unit initiates the anti-frost protection and all buttons on control panel (except for power button) are inactive.
Once the tube temperature
≧
46.4
℉
(
8
℃)
, the protection is relieved to recover into original status, and compressor
apply to 3-minute delay protection.
2.
Water-full safety alarm and shut
–off protection function:
Warning sounds when the water volume reached its alarm level in water tank, and unit is automatically stop working,
both water-
full indicator and “FL” on LED window is flashing. You need to drain the condensate for unit to
automatically recover operation. (For more information about how to drain, refer to the “Drainage Instruction”
please).
3.
Delay protection function of compressor
This unit offers restart protection to compressor. Except that the compressor may start immediately when the unit is
energized at first time, there is 3-minute start delay after compressor is shut down.
Handling and Transportation
1.
Handle and move the unit
Hold handles on side panels to move the unit in upright position (As shown in Photo below).
Note:
Make the unit in the upright position whatever handling or moving it.
Drain the water in the unit completely to prevent water leakage and wet the floor or carpet before handling or
moving the unit.