Dell W-IAP277 Скачать руководство пользователя страница 8

8

Dell Networking W-IAP277 Outdoor Instant Access Point

| Installation Guide

Figure 6  

Grounding the IAP

Connecting the Ethernet Cable

To connect the Ethernet cable to the IAP, complete the following steps using the cable glands included in the 
IAP package.

Figure 7  

Installing a Cable Gland 

1. Slide the sealing nut over the cable (without the RJ45 connector attached to the end).
2. Slide the clamping ring over the cable.
3. Using a crimping tool, attach the shielded RJ45 connector to the end of the cable.
4. Remove the weatherproof cap on the Ethernet port. 
5. Insert the RJ45 connector to the Ethernet port.
6. Screw the clamping ring onto the Ethernet port.
7. Screw the sealing nut onto the clamping ring.

Connecting the Power Cable

WARNING:  Failure to use the included Ethernet cable glands can lead to connectivity and PoE issues.

NOTE:  The Ethernet cable is not included and must be purchased separately. Purchase a suitable UV-resistant, outdoor rated, CAT 
5E or better RJ45 cable for use with the IAP.

Sealing Nut

Clamping Ring

CAT 5E or Better Cable

Seal

NOTE:  The seal inside the clamping ring by factory default is applicable for cables with 5-8.5 mm diameter. In the cable gland kit, 
another seal is provided for use with the cables with 7-10 mm diameter.

CAUTION:  Installation and service of Dell products should be performed by Professional Installers in a manner that is consistent 
with the electrical code in force in the jurisdiction of deployment. In many countries this will require a licensed electrician to 
perform this operation. In Japan, this is a Certified Electrician by Ministry of Economy, Trade, and Industry.

Содержание W-IAP277

Страница 1: ...tailed hardware overview of the W IAP277 Instant access point Before You Begin on page 5 provides key questions to ask and items to consider when deploying an outdoor wireless network Installing the IAP on page 7 describes the multi step process for successful installation and deployment of the W IAP277 Instant access point Safety and Regulatory Compliance on page 12 provides safety and regulatory...

Страница 2: ... Point Installation Guide NOTE Inform your supplier if there are any incorrect missing or damaged parts If possible retain the carton including the original packing materials Use these materials to repack and return the unit to the supplier if needed ...

Страница 3: ...tus Table 1 W IAP277 LED Status during Boot Up LED Color State Meaning System LED Off No power to IAP Red Initial power up Green Flashing IAP booting Green Steady IAP ready and 1000Mbps Ethernet link established The LED turns off after 1200 seconds Green Yellow 6 seconds period IAP ready and 10 100Mbps Ethernet link established The LED turns off after 1200 seconds AC Power Interface LAN Port WAN P...

Страница 4: ... 1 Power off the IAP 2 Press and hold the reset button using a small narrow object such as a paperclip 3 Power on the IAP without releasing the reset button The system LED will flash within 5 seconds 4 Release the reset button The system LED will flash again within 15 seconds indicating that the reset is completed The IAP will now continue to boot with the factory default settings AC Power Interfa...

Страница 5: ...iew Before You Begin Mounting Holder CAUTION To meet regulatory restrictions the Instant access point must be professionally installed CAUTION FCC Statement Improper termination of access points installed in the United States configured to non US model controllers will be in violation of the FCC grant of equipment authorization Any such willful or intentional violation may result in a requirement ...

Страница 6: ...the intended coverage area and should be free from obstructions or obvious sources of interference These RF absorbers reflectors interference sources will impact RF propagation and should have been accounted for during the planning phase and adjusted for in the RF plan CAUTION EU Statement Lower power radio LAN product operating in 2 4 GHz and 5 GHz bands Refer to the Dell Networking W Series Inst...

Страница 7: ... AP After the W IAP277 Instant access point is mounted it must be grounded before powering up The grounding wire should be 8 AWG 1 Peel the cover of one end of the grounding wire and place the bare grounding wire into the included copper lug and press firmly with the crimping pliers 2 Fasten the copper lug to the grounding hole on the IAP with the included M4 x8 screw as shown in Figure 6 NOTE Ser...

Страница 8: ...ng the Power Cable WARNING Failure to use the included Ethernet cable glands can lead to connectivity and PoE issues NOTE The Ethernet cable is not included and must be purchased separately Purchase a suitable UV resistant outdoor rated CAT 5E or better RJ45 cable for use with the IAP Sealing Nut Clamping Ring CAT 5E or Better Cable Seal NOTE The seal inside the clamping ring by factory default is...

Страница 9: ...Japan this would is a Certified Electrician by Ministry of Economy Trade and Industry The use of plugs with infrastructure equipment is suitable only for temporary installs where nuisance tripping of GFI plugs is considered tolerable Should it be desired to attach a plug to the cable assemblies then the installer is expected to follow all directions provided with the plug end in a fashion consiste...

Страница 10: ... interface 2 Insert the power cable connector into the power interface and hand fasten the locknut Verifying Post Installation Connectivity The integrated LEDs on the IAP can be used to verify that the IAP is receiving power and initializing successfully see Table 1 and Table 2 Refer to the Dell Networking W Series Instant Quick Start Guide for details on verifying post installation network connec...

Страница 11: ... auto sensing Ethernet RJ 45 Interfaces MDI MDX Power over Ethernet IEEE 802 3at compliant 48VDC 0 6A Power 100 240 VAC 50 60 Hz from external AC power source PoE support on WAN port 802 3at compliant PoE sourcing devices Environmental Operating Temperature 40ºC to 65ºC 40ºF to 150ºF Humidity 5 to 95 non condensing Storage Temperature 40ºC to 70ºC 40ºF to 158ºF For additional specifications on thi...

Страница 12: ...enna Increase the separation between the equipment and receiver Connect the equipment to an outlet on a circuit different from that to which the receiver is connected Consult the dealer or an experienced radio or TV technician for help NOTE For country specific restrictions and additional safety and regulatory information refer to the Dell Networking W Series Safety Environmental and Regulatory In...

Страница 13: ...ay be obtained upon request from Aruba Networks International Ltd Building 1000 Citygate Mahon Cork Ireland Please include the regulatory model number located on the product s regulatory nameplate with the request China RoHS Dell products also comply with China environmental declaration requirements and are labeled with the EFUP 10 label shown at the left 10 ᆇ 䋼ໄᯢ Hazardous Materials Declaration ᆇ...

Страница 14: ...ay not cause interference and 2 this device must accept any interference including interference that may cause undesired operation of the device Canadian Caution This radio transmitter identify the device by certification number or model number if Category II has been approved by Industry Canada to operate with the antenna types listed below with the maximum permissible gain and required antenna i...

Страница 15: ...Dell Networking W IAP277 Outdoor Instant Access Point Installation Guide 15 This page is intentionally left blank ...

Страница 16: ...www arubanetworks com open_source Includes software from Litech Systems Design The IF MAP client library copyright 2011 Infoblox Inc All rights reserved This product includes software developed by Lars Fenneberg et al Legal Notice The use of Aruba Networks Inc switching platforms and software by all individuals or corporations to terminate other vendors VPN client devices constitutes complete acce...

Отзывы: