Relative humidity specifications
Table 13. Relative humidity specifications
Relative humidity
Specifications
Storage
5% to 95% RH with 33°C (91°F) maximum dew point. Atmosphere
must be non-condensing at all times.
Operating
10% to 80% relative humidity with 29°C (84.2°F)
Maximum vibration specifications
Table 14. Maximum vibration specifications
Maximum vibration
Specifications
Operating
0.26 Grms at 5 Hz to 350 Hz (all operation orientations).
Storage
1.88 Grms at 10 Hz to 500 Hz for 15 min (all six sides tested).
Maximum shock specifications
Table 15. Maximum shock specifications
Maximum shock
Specifications
Operating
24 executed shock pulses 6 G in the positive and negative x, y, z
axis for up to 11 ms (four pulses on each side of the system).
Storage
Six consecutively executed shock pulses of 71 G in the positive and
negative x, y, z axes for up to 2 ms (one pulse on each side of the
system).
Maximum altitude specifications
Table 16. Maximum altitude specifications
Maximum altitude
Specifications
Operating
3048 m (10,000 ft)
Storage
12,000 m (39,370 ft)
Technical specifications