NOTE: Do not return the storage controller battery with the failed storage controller. A new battery
is not included with a replacement storage controller.
Identify the Failed Storage Controller
To determine which storage controller failed, use the Dell Storage Client.
1.
Click the
Hardware
tab.
2.
In the
Hardware
tab navigation pane, select and expand the failed storage system.
3.
In the
Hardware Alerts
area, find the hardware alert that identifies the enclosure with the failed
storage controller.
Figure 27. Hardware Alert Identifying the Enclosure with the Failed Storage Controller
4.
In the Hardware tab navigation pane, expand the
Enclosures
entry.
5.
Click
I/O Modules
. The status of each storage controller is displayed in the
I/O Modules
tab.
6.
Select the failed storage controller to display its location in the
IO Module View
tab.
Replacing SCv2080 Storage System Components
37