PS6500 Hardware Maintenance
Maintaining Control Modules
3-4
To display the firmware version running on an array, examine the GUI Member Controllers window or use the CLI
member select show controllers
command.
Control Module Handling Requirements
Follow these control module handling guidelines:
•
Protect control modules from electrostatic discharge.
When handling a control module, always wear an
electrostatic wrist strap or use a similar protective device. See
Protecting Hardware from Electrostatic
Discharge
on page 1-7.
•
Do not remove a control module from an array while the control modules are synchronizing.
When
synchronization completes, a console message will appear. Also, the ACT LED on the secondary control
module will be orange.
•
Do not leave a control module slot empty.
In an array with one control module, always attach a blank face
plate to the empty control module slot.
•
Store control modules properly.
Store a control module in its original packaging or in an antistatic bag or
place the control module on a surface protected from electrostatic discharge.
Removing a Control Module
If a control module fails, replace it with a functioning control module as soon as possible. Do not remove a failed
control module until you are ready to replace it. You can temporarily remove a functioning control module to
replace a micro SD card.
Note:
For proper cooling, do not leave a control module slot empty. If an array will operate for a long time with
only one control module, you must install a blank control module in the empty slot. You can order a blank
control module from your PS Series array service provider.
You can remove a control module without shutting down the array if the remaining control module has at least one
connected and functioning network interface. However, if you remove the active control module (the LED labeled
ACT will be green), there will be a short interruption as failover to the secondary control module occurs.
Otherwise, if possible, cleanly shut down the array before removing the module, as described in
Shutting Down
and Turning Off Power to an Array
on page 1-13.
If you remove the active control module, there will be a short interruption as failover to the secondary control
module occurs.
Caution:
Do not remove a control module from an array while the control modules are still synchronizing. A
message will appear on the console when synchronization completes. The ACT LED on the secondary
control module will be orange when synchronization completes.
Before removing a control module:
•
Attach an electrostatic wrist strap, as described in
Protecting Hardware from Electrostatic Discharge
on
page 1-7.
•
Disconnect any serial or network cables attached to the control module. Optionally, re-attach the network
cables to the functioning control module to provide uninterrupted data access.