PS6500 Hardware Maintenance
Basic Array Information
1-14
The serial connection must have the following characteristics:
– 9600 baud
– One STOP bit
– No parity
– 8 data bits
– No flow control
2. When prompted, log in to a group administration account with read-write access, such as the
grpadmin
account.
3. Enter the
shutdown
command.
4. When it is safe to turn off the array, remove the bezel and press the blue power button on the front panel.
If you are using a serial connection to shut down an array, it is safe to turn off power when the “press any key”
message appears. (Pressing any key will restart both control modules.)
If you are using a network connection, the session will be disconnected before the array is fully shut down. It is
safe to turn off power when the ACT LED on each control module is off (not lit).
5. To fully remove power from the array, disconnect each power supply from its power source. Note that the array
will no longer be grounded if you disconnect all the power cables.
Note:
If you turn off power to an array, but two or more functioning power supply and cooling modules are
connected to a source of power, the array will enter standby mode.
For information about turning on power and restarting an array, see
Turning on Power to an Array
on page 1-13.
Returning Hardware
You must return hardware in the original packaging or in authorized packaging. Returning hardware in
unauthorized packaging may void your warranty.
If you receive a replacement part from your PS Series support provider, return the failed hardware in the packaging
in which the replacement part was shipped.
Contact your PS Series support provider for more information about returning hardware.